Electrical installation
31
Electrical installation
WARNING!
Follow the safety instructions given in this manual and
in the Hardware Manual of the drive.
General cabling instructions
Arrange the network cable as far away from the motor cables as
possible. Avoid parallel runs. Use bushings at cable entries.
Ethernet connection
The network cable is connected to the RJ45 connector (X1) on the
RETA-01 module. Standard CAT 5 UTP and CAT 5 STP cables
can be used. In case CAT 5 STP is used, the cable shield is
internally connected to drive frame through the module.