9.7
Removing the cartridge group
Fig. 27: Moving out cartridge group 1
1. Remove the O-ring (42010).
2. Loosen and remove the screws (42099).
3. Fit bracket (90030) and fit swivel lifting eye (90657) to cartridge group with
screws (90900).
4. Move in one plate (90031).
5. To secure, fit plate (90032) with screw (90656) and nut (90415).
6. Secure lifting gear to swivel lifting eye (90657).
Fig. 28: Moving out cartridge group 2
7. Evenly press off cartridge group by screwing three press-off screws (90901) into the des-
ignated holes.
8. Carefully move out cartridge group.