30 Program features
String current deviation detection (-SX model)
A faulty string, for example, due to high amount of shadowing or obstacles can be
detected if the current in one string deviates significantly from other strings. The feature
can be enabled with parameter
and it has several
configuration parameters.
Inverter can be configured to use either relative or absolute comparison between string
currents with parameter
. If there is a major difference, a warning
is indicated after the delay set in parameter
. The value that the
individual currents are compared against is the reference value of which type is defined in
parameter
. The reference value can be selected to be either the
maximum or the mean value of the connected strings.
•
In
absolute mode
, individual string currents are compared against the reference
value in amperes. If the difference is greater than the value set in parameter
in amperes, a warning is indicated after a delay.
•
In
relative comparison mode
, individual string currents are compared against the
reference value in percent. The limit is defined in parameter
. If a string current is greater or lower than the reference value, a warning is
indicated after the delay time is elapsed. In addition, the reference value must be
greater than the value defined in parameter
to avoid
nuisance warnings at very low currents.
Settings
Summary of Contents for PRO-33.0-TL Series
Page 1: ...ABB solar inverters Service menu guide PRO 33 0 TL string inverters ...
Page 4: ......
Page 8: ...8 ...
Page 12: ...12 Service menu ...
Page 36: ...36 Program features ...
Page 100: ...100 Parameters ...
Page 112: ...112 Tools ...
Page 121: ......
Page 122: ...www abb com solarinverters Contact us 3AXD50000015823 Rev C EN 2017 06 29 ...