1HC0075079 AB
| EN
| Operating instructions
|
5
Thanks to its extra high energy absorbing capability, the POLIM®4.5 ID is especially suited for over-
voltage protection of
locomotives and other apparatuses in railway applications
The POLIM®4.5 ID is intended to be used indoors.
3.3
Technical data
The technical data, dimensions and weights are specified in the following documents:
Surge arrester POLIM®4.5 ID for applications in d.c. systems in the pamphlet 1HC0075852.
POLIM®4.5 ID dimensional drawing HAWA 380212
3.3.1
Technical data on the surge arrester
The rating plate contains the following data:
Data
Meaning
POLIM®4.5 ID
Complete type designation with specification of the maximum permissible
continuous operating voltage U
c
I
n
= 40 kA
Nominal discharge current
U
c
= ... kV
dc
Maximum permissible continuous operating voltage (d.c. voltage)
U
r
= ... kV
dc
Rated voltage (d.c. voltage)
HA …
Serial number
xx-20xx
Date of manufacture: month-year
3.3.2
Application guidelines
The following guidelines apply for the use of POLIM®4.5 ID surge arresters:
„Application guidelines“ for railway systems, pamphlet 1HC0075573
3.3.3
Recommended torques and screw-in depths
The specified values in the table below apply for steel bolts of strength class 8.8 in aluminum nut
threads.
Thread
Position
Maximum
torque
[Nm]
Minimum
screw-in depth
[mm]
Maximum
screw-in depth
[mm]
M12
Head end / High
voltage terminal
48
18
25
3.3.4
Behaviour in fire
The silicone housing of the surge arrester is self-extinguishing.