Parameter addresses
System parameters 10H
Parameter address (Offset)
Data type
Function
Value range and coding
0000H
Byte
Speed 1
00H = off
01H = 2.5 mm/h
02H = 5 mm/h
03H = 10 mm/h
04H = 20 mm/h
05H = 30 mm/h
06H = 40 mm/h
07H = 60 mm/h
08H = 120 mm/h
09H = 240 mm/h
0AH = 300 mm/h
0BH = 600 mm/h
0CH = 1200 mm/h
0001H
Byte
Speed 2
as speed 1
0003H
Byte
Mode
00H = Mode A
01H = Mode B
02H = Mode C
03H = Mode D
04H = Mode E
0004H
Word
Cycle time of measured value
printout
0003H = 3 s
...
0168H = 360 s
0006H
Byte
Delay for exctrenal control
00H...1EH = 0...30 s
0008H
Byte
Number of event markers
00H = without
01H = 1
..
0AH = 10
0009H
Byte
Date / time format
00H = European
01H = American
000AH
Byte
Type of simulation
00H = off
01H = Ramp
02H = Sinus
03H = Step (10%)
000BH
Word
Simulation period
0014..07D0H = 20...2000 s
000DH
Time
Time for external clock
synchronisation
Hour (high byte)
00...23 = 00...17H
Minute (low byte)
00...59 = 00...3BH
000FH
Byte
Baud rate
00H = 600
01H = 1200
02H = 2400
03H = 4800
04H = 9600
05H = 19200
0010H
Byte
Device address
0...126 = 00..7EH
0011H
Byte
Language selection
00H = Scale device
01H = German
02H = English
03H = French
0012H
Byte
Alarm acknowledgment
00H = off
01H = manual
02H = automatic
10
Parameters