MN1949WEN
Introduction 2-1
Introduction
2 Introduction
2.1
Analog I/O option features
The Analog I/O option is available as a customer-fitted option for the MotiFlex
e
100 range of
drives. The option adds a number of features to the drive:
Four ±10 V differential analog inputs with 16-bit resolution.
Four ±10 V single-ended analog outputs with 16-bit resolution.
The option card may be inserted in either of the expansion slots, located on the top and
bottom panel of the drive.
2.1.1 Installation
Before touching the option card, be sure to discharge static electricity from your
body and clothing by touching a grounded metal surface. Alternatively, wear an
earth strap while handling the card.
1.
Choose carefully which of the option
slots (top or bottom) to use. The choice
will often depend on the best route for
the wiring that will lead to the option
card.
2.
Pull off the drive’s top or bottom front
panel cover (as appropriate). Remove
the option slot cover’s retaining screw.
3.
Insert a screwdriver under the edge of
the option slot cover and gently lever
out the cover.
NOTICE
2
Figure 2-1: Loosen retaining screw
Figure 2-2: Lift out cover
Summary of Contents for OPT-MF-001
Page 1: ...MN1949 Analog I O Option ...
Page 2: ......
Page 4: ...ii Contents MN1949WEN ...
Page 14: ...3 6 Input Output MN1949WEN ...
Page 15: ...MN1949WEN Input Output 3 7 ...
Page 16: ...3 8 Input Output MN1949WEN ...
Page 18: ...Comments MN1949WEN Thank you for taking the time to help us ...