Note
Equipment
For control cables up to 15m and
mains supply voltage up to 400
VAC, a 30 mA earth fault protec-
tion can be used if it is Hager
CDH440R, CDH440D or ABB F204
B-40/0,03.
External earth fault protection (residual current circuit
breaker, Class B for frequency converters, 300mA)
32 A, Class K.
Note
For installations according to UL
requirements, use Circuit Breaker,
Type SU203M-K32, manufactured
by ABB.
External fuse or circuit breaker
See
Standard toolkit for controller
Standard toolkit
Circuit diagram - OmniCore
V400XT
,
3HAC082020-008
Circuit diagram
Connecting the power
The following procedure describes how to connect the main power to the controller.
CAUTION
Always inspect the connector for dirt or damage before connecting it to the
controller. Clean or replace any damaged parts.
Action
xx2100001259
Connect the main power cable to the incom-
ing mains connector X0 and lock it by press-
ing the locking levers.
Tip
When you hear a clear clicking sound, it is
locked.
1
Line fusing
An external circuit breaker (class K) or fuse must be added to prevent short circuit
and overload. The full load current for the robot is marked on the controller name
plate, and is also displayed in section
.
Product manual - OmniCore V400XT
85
3HAC081697-001 Revision: A
© Copyright 2022-2023 ABB. All rights reserved.
3 Installation and commissioning
3.5.6 Connecting incoming mains and protective earth to the controller
Continued
Summary of Contents for OmniCore V400XT
Page 1: ...ROBOTICS Product manual OmniCore V400XT...
Page 180: ...This page is intentionally left blank...
Page 338: ...This page is intentionally left blank...
Page 342: ...This page is intentionally left blank...
Page 428: ...This page is intentionally left blank...
Page 460: ...This page is intentionally left blank...
Page 464: ......
Page 465: ......