5.3.4 Replacing the cable grommet assembly
Location
The illustration shows the location of the cable grommet assembly on the controller.
xx2200002163
Note
The end user needs to install proper grommets according to the diameter of the
cables which need to go through the grommet.
Incorrect use of grommets will affect ingress protection, EMI/EMC and
temperature.
It is recommended to use
icotek
KT grommet.
Required spare parts
Note
The spare part numbers that are listed in the table can be out of date. See the
latest spare parts of the OmniCore V250XT Type B via myABB Business Portal,
.
Note
Article number
Spare part
3HAC066396-001
Cable grommet asm
3HAC084125-001
Harness network connection
2xM12
3HAC084103-001
Harness network connection
1xM12
3HAC069954-001
Blind plate
3HAC070894-001
Harness Ethernet comm. 5xM12