3.5.6 Connecting and detaching a FlexPendant
Introduction
When the controller is in automatic mode the FlexPendant can be detached from
the controller without interrupting ongoing processes. This is possible only if the
logged in user has the
Safety Services
grant.
CAUTION
Before detaching the FlexPendant, another emergency stop shall be available
on the robot/robot system.
CAUTION
Without a connected FlexPendant, there is no visual identification of the operating
mode.
CAUTION
A FlexPendant that is not connected to the robot or robot system cannot initiate
emergency stops or protective stops. This must be stored out of reach and sight
so that it cannot be mistaken for being in use.
CAUTION
The FlexPendant connector can only be used to connect a FlexPendant and
CANNOT be used to connect any other devices.
All external safety devices must be connected from the customer interface on
robot signal exchange proxy.
Location of FlexPendant connector
The FlexPendant connector is located on the front panel on the controller.
Detaching the FlexPendant in automatic mode
Use the following procedure to detach the FlexPendant in automatic mode:
1 On the status bar, tap the
QuickSet
button.
2 Tap the
Logout/Restart
tab.
3 In the
FlexPendant
section, tap
Detach FlexPendant
.
Continues on next page
76
Product manual - OmniCore C90XT
3HAC073706-001 Revision: D
© Copyright 2020-2021 ABB. All rights reserved.
3 Installation and commissioning
3.5.6 Connecting and detaching a FlexPendant
Summary of Contents for OmniCore C90XT
Page 1: ...ROBOTICS Product manual OmniCore C90XT ...
Page 50: ...This page is intentionally left blank ...
Page 350: ...This page is intentionally left blank ...
Page 354: ...This page is intentionally left blank ...
Page 412: ...This page is intentionally left blank ...
Page 444: ...This page is intentionally left blank ...
Page 448: ......
Page 449: ......