ABB-Welcome M

Operations

  |

— 7 —

4.2

Settings

4.2.1

Ringtone type settings

Pos: 21 /Di nA4 - A nleitu ngen  Onlin e/In halt/KNX/Do orEnt ry/83 220 -AP-xxx/Be dienel eme nte  - 8 322 0-AP-xxx  @ 18\ mo d_1 3032 128 536 05_ 15.d ocx @  103 673  @  @  1

1.  Hold 

"

 +

 " for about 3 seconds to enter the system setting mode (with

blue LED & red LED flashing simultaneously).

2. Press

 to set the next ringtone type for the door bell.

3. Press

  to set the next ringtone type for a call from an outdoor station.

4. Press

 to set the next ringtone type for an intercom call from other apartments

or the guard unit.

5.  Hold 

"

 +

 " for about 3 seconds to save the selected ringtone type and

exit the system setting mode..

4.2.2

Default outdoor station settings

Pos: 21 /Di nA4 - A nleitu ngen  Onlin e/In halt/KNX/Do orEnt ry/83 220 -AP-xxx/Be dienel eme nte  - 8 322 0-AP-xxx  @ 18\ mo d_1 3032 128 536 05_ 15.d ocx @  103 673  @  @  1

1. 

Pickup the handset, hold

 for about 3 seconds to enter the default outdoor

station setting mode.

2. Press

 button to set the address of the default outdoor station. (the value is

indicated by the flash times of the red LED;  it can be set from 1 to 9, default

setting: 1).

3. Hold

 for about 3 seconds or put down the handset to save the setting and

exit the settings mode.

4.2.3

Programming the auxiliary buttons

Pos: 21 /Di nA4 - A nleitu ngen  Onlin e/In halt/KNX/Do orEnt ry/83 220 -AP-xxx/Be dienel eme nte  - 8 322 0-AP-xxx  @ 18\ mo d_1 3032 128 536 05_ 15.d ocx @  103 673  @  @  1

Each programmable button is available only after setting. These buttons can be

set for different functions, e.g. call guard unit, intercom call or controls switch

actuator.

1. 

Enter the programming mode

Hold the programmable button for 3 seconds in the standby mode to enter the

programming mode.

2. 

Set the function for each programmable button

Check the needed function, and press

 to program the corresponding function

code which is indicated by the flash times of the blue LED.

 The function code can be changed: 0->1->2->3->4->5->0.

Summary of Contents for M22001 series

Page 1: ...s 2 DinA4 Anl eitun gen Online Inh alt KNX Doo rEntry 832 20 AP xxx Tit elblat t 832 20 AP xxx ABB 1 9 m od_ 132 3249 806 476 _15 docx 11 108 4 1 M22001 M22002 M22003 Audio handset indoor station E nd...

Page 2: ...Environment 3 3 1 ABB devices 3 4 Operations 5 4 1 Standard operations 5 4 1 1 Control elements 5 4 2 Settings 7 4 2 1 Ringtone type settings 7 4 2 2 Default outdoor station settings 7 4 2 3 Programm...

Page 3: ...d operates exclusively with components from this system The device must only be installed in dry indoor rooms Pos 10 B usch J aeg er Neus truk tur M odul Strukt ur O nline Doku me ntatio n be rsch rif...

Page 4: ...the legal requirements in particular the laws governing electronic and electrical devices and the REACH ordinance EU Directive 2002 96 EG WEEE and 2002 95 EG RoHS EU REACH ordinance and law for the im...

Page 5: ...r Bet rieb 18 mo d_1 302 768 8209 65_ 15 docx 10 3540 2 1 4 1 Standard operations Pos 20 Di nA4 A nleitu ngen Onlin e Ueb ersc hrift en 3 Bedie nele men te 20 mod _13 232 6022 055 9_1 5 do cx 1 116 47...

Page 6: ...intercom 3B Default function of button 1 is the release of the lock connected with an outdoor station COM NC NO 4 Three level selector for call volume adjustment maximum medium mute 5 LED Red indicat...

Page 7: ...andset hold for about 3 seconds to enter the default outdoor station setting mode 2 Press button to set the address of the default outdoor station the value is indicated by the flash times of the red...

Page 8: ...is called The address can be set from 01 to 99 Hold this programmable button again for 3 seconds until the LED begins to flash tens digit or units digit address is other than 0 or lights on tens digit...

Page 9: ...783 3 1 X100 X10 X1 Jumper to set the address of the indoor station EXAMPLE setting address 024 2 Master Slave function Only one indoor station in each apartment must be set as Master Jumper should be...

Page 10: ...e n 832 20 AP x xx 1 8 m od_ 130 321 285 4559 _15 docx 1 037 05 1 Designation Value Operating temperature 10 C 55 C Storage temperature 40 C 70 C Protection IP 30 Single wire clamps 2 x 0 28 mm 2 x 1...

Page 11: ...k enn tnisse 18 mo d_1 302 774 384 017_ 15 docx 10 356 4 2 1 6 1 Requirements for the electrician Warning Electric voltage Install the device only if you have the necessary electrical engineering know...

Page 12: ...100 240 V wires Do not use common cables for the connecting wires of the door openers and wires of the system bus Avoid bridges between different cable types Use only two wires for the system bus in a...

Page 13: ...960 458 _15 docx 10 342 4 2 1 6 3 Mounting Pos 85 1 DinA4 Anleit ung en O nline I nhal t KNX DoorE ntry 832 20 AP xxx Mo nta ge Mo dule Mon tag e Mon tage dos e 83 220 AP xxx 19 mod _132 325 040 684 8...

Page 14: ...vice and connect it with reference to the graphics The insulated section of the cable end must not be longer than 10mm Settings Set addresses for the preferred outdoor stations and the address for the...

Page 15: ...he upper side of the device on the lock in lugs and then press the bottom side onto the bottom part of the device until it is caught by the clamp The installation of the indoor station is now complete...

Page 16: ...Tex tma rke Ba ckcove r We reserve the right to at all times make technical changes as well as changes in the contents of this document without prior notice The detailed specifications agreed to at th...

Reviews: