56
Accessing the linearization function
To access the linearization function:
1
Select
Device Setup
>
Linearization
>
Setup
>
Output Type
.
2
Press
Edit
.
3
Highlight the measurement value that you want to use (
Level
,
Volume
or
Flow
) and press
OK
.
This activates a series of parameters that will be explained and configured below.
Setting linearization input unit
To set the input unit used by the linearization function:
1
Select
Device Setup
>
Linearization
>
Setup
>
Input Unit
.
2
Press
Edit
.
3
Highlight the unit that will be used to input data into the linearization calculation and press
OK
.
Setting linearization output unit
To set the volume of flow output unit resulting from the linearization calculation:
1
Select
Device Setup
>
Linearization
>
Setup
>
Output Unit
.
2
Press
Edit
.
3
Highlight the level, volume or flow unit that will be used with data output from the linearization
calculation and press
OK
.
Setting maximum level, volume or flow value
To set the maximum level, volume of flow value to measure: :
1
Select
Device Setup
>
Linearization
>
Setup
>
Maximum
.
2
Press
Edit
.
3
Set the maximum level, volume or flow value that the instrument will have to measure and press
OK
.
Setting vessel parameters
NOTICE
The following parameters are available if you selected
Volume
as your output type (see
“Accessing the linearization function” on page 56).
When measuring volumes, you must set the following vessel (tank) parameters:
• Orientation
• Diameter
• Length
Setting the vessel orientation
To set the vessel orientation:
1
Select
Device Setup
>
Linearization
>
Volume Calculation
>
Cylinder Orientation
.
2
Press
Edit
.
3
Highlight the orientation of your tank (
Vertical
or
Horizontal
) and press
OK
.
Summary of Contents for LWT300 series
Page 1: ... USER GUIDE LWT300 series Guided wave radar level transmitter Modbus ...
Page 36: ...Page intentionally left blank ...
Page 40: ...Page intentionally left blank ...
Page 66: ...Page intentionally left blank ...
Page 70: ...Page intentionally left blank ...
Page 76: ...Page intentionally left blank ...
Page 96: ...Page intentionally left blank ...
Page 98: ...Page intentionally left blank ...
Page 104: ...Page intentionally left blank ...
Page 105: ...Page intentionally left blank ...
Page 106: ...Page intentionally left blank ...
Page 107: ......