background image

 

 

 
 
 
 
 

Summary of Contents for LP

Page 1: ...INSTRUCTION MANUAL LINEAR PISTON ACTUATORS Type LP Simple Cylinder Actuators PN25008 ...

Page 2: ...t is subject to change without notice ABB Inc reserves the right to make minor changes to this publication such as company name logos as well as other minor corrections without necessarily changing the publication number ABB Inc its affiliates employees and agents and the authors of and contributors to this publication specifically disclaim all liabilities and warranties express and implied includ...

Page 3: ...ORS INSTRUCTION MANUAL 1 TABLE OF CONTENTS READ FIRST 2 1 0 SPECIFICATIONS FEATURES 3 2 0 THRUST RATINGS 4 3 0 MODEL NUMBER DETAILS 5 4 0 OUTLINE DIMENSIONS 6 2 in Sizes LP10 6 4 in Sizes LP20 7 6 in Sizes LP32 8 5 0 PARTS 9 ...

Page 4: ...uipment Contact ABB Inc for authorization prior to returning equipment Read these instructions before starting installation save these instructions for future reference WARNING Stay clear of moving components when performing procedures that require the equipment to be energized The equipment can operate automatically There is a risk of entanglement of body parts if caution is not observed When pos...

Page 5: ...es provide a linear actuation solution that is ideally suited for applications like Windbox dampers The conventional assembly which uses the AV Positioner series offers a high temperature option up to 25 o F In comparison our digital solution allows for operation up to 185 o F plus the added features of digital control LP sizes range from a 2 5 diameter cylinder with a 5 stroke 2 5 x 5 up to a 12 ...

Page 6: ...he area of the piston is A πD2 4 Subtract approximately 10 for friction losses and because the rod side of the piston has less area An example is shown for an 80 psi air supply To find the lever length that would result in 90o rotation of the damper shaft multiply the cylinder stroke length by 0 707 Please refer to the individual Product Specifications for details on the AV and TZID C Positioner p...

Page 7: ...All other positioners have a 185 o F maximum ambient Buna N seals are recommended unless temperatures 200 o F dictate Viton Please refer to the individual Instruction Books for the AV and the TZID C for details on the two types of Positioners Nomenclature Digits 1 thru 4 5 6 7 8 9 10 Cylinder Size 2 d X 5 stroke LP10 4 d X 4 stroke LP20 6 d X 8 stroke LP30 6 d X 16 stroke LP 32 8 d X 8 stroke LP40...

Page 8: ...LP LINEAR PISTON ACTUATORS INSTRUCTION MANUAL 6 4 0 OUTLINE DIMENSION DRAWINGS Certified Drawings available on request LP 10 2 5 x 5 Linear Piston Shown with TZID C Smart Positioner ...

Page 9: ...LP LINEAR PISTON ACTUATORS INSTRUCTION MANUAL 7 LP 20 4 x 4 Linear Piston Shown with AV15 Positioner ...

Page 10: ...LP LINEAR PISTON ACTUATORS INSTRUCTION MANUAL 8 LP 32 6 x 16 Linear Piston Shown with AV15 Positioner ...

Page 11: ...LP LINEAR PISTON ACTUATORS INSTRUCTION MANUAL 9 5 0 PARTS ...

Page 12: ...LP LINEAR PISTON ACTUATORS INSTRUCTION MANUAL 10 ...

Page 13: ...LP LINEAR PISTON ACTUATORS INSTRUCTION MANUAL 11 ...

Page 14: ...LP LINEAR PISTON ACTUATORS INSTRUCTION MANUAL 12 ...

Page 15: ...LP LINEAR PISTON ACTUATORS INSTRUCTION MANUAL 13 ...

Page 16: ...LP LINEAR PISTON ACTUATORS INSTRUCTION MANUAL 14 ...

Page 17: ......

Page 18: ...e Road Warminster PA 18974 USA Tel 215 674 6000 FAX 215 674 7183 ABB Instrumentation Ltd Howard Road St Neots Cambs England PE19 3EU Tel 44 0 1480 475 321 FAX 44 0 1480 217 948 ABB Instrumentation S p A Via Sempione 243 20016 Pero Milano Italy Tel 39 02 33928 1 Fax 39 02 33928 240 ABB Automation Products GmbH Industriestr 28 D 65760 Eschborn Germany Tel 49 0 6196 800 0 Fax 49 0 6196 800 1849 PN250...