Step 6: There are 3 different output options for ISO TX.
Option 1: Connect Y3 and N or Y1 and N to get 115V voltage output.
Option 2: Use jumper to short N and Y3 firstly, connect Y2 and N to get 208V voltage
output.
Option 3: Use jumper to short N and Y3 firstly, connect Y1 and N to get 230V output.
Step 7: Connect the temperature signal cable between the temperature signal port of ISO
TX and dry contact terminal of UPS.
Step 8: Connect the input cables of UPS according to related user manual.