8.3 Updating revolution counters
Introduction
This section describes how to do a rough calibration of each manipulator axis by
updating the revolution counter for each axis, using the FlexPendant.
Step 1 - Manually running the manipulator to the synchronization position
Use this procedure to manually run the manipulator to the synchronization position.
Note
Action
Select axis-by-axis motion mode.
1
See
.
Jog the manipulator to align the synchron-
ization marks.
2
Step 2 - Updating the revolution counter
with the FlexPendant on page 269
When all axes are positioned, update the
revolution counter.
3
Step 2 - Updating the revolution counter with the FlexPendant
Use this procedure to update the revolution counter with the FlexPendant (IRC5).
Action
On the
ABB
menu, tap
Calibration
.
xx1500000942
1
Continues on next page
Product manual - IRBP /D2009
269
3HAC037731-001 Revision: T
© Copyright 2010-2020 ABB. All rights reserved.
8 Calibration information
8.3 Updating revolution counters
Summary of Contents for IRBP
Page 1: ...ROBOTICS Product manual IRBP D2009 ...
Page 38: ...This page is intentionally left blank ...
Page 70: ...This page is intentionally left blank ...
Page 250: ...This page is intentionally left blank ...
Page 264: ...This page is intentionally left blank ...
Page 314: ...This page is intentionally left blank ...
Page 330: ...This page is intentionally left blank ...
Page 333: ......