5.6 Lubrication activities
5.6.1 Lubricating the current collector
DANGER
Turn off all electrical power, hydraulic and pneumatic pressure supplies before
entering the workspace of the manipulator.
See also
.
Current collector
The function of the current collector is to transfer the weld current through the
rotary unit. This takes place through a spring-loaded contact bar against the shaft.
The contact bar needs to be lubricated approximately after 400 hours of operation.
This should be done using a special grease, P34 from Nies, article number:
0501869-001.
Required equipment
Note
Equipment
Grease type: P34 from Nies. Article number:
0501869002.
Grease
Standard tools IRBP on page 312
Standard tools
Grease gun
Continues on next page
182
Product manual - IRBP /D2009
3HAC037731-001 Revision: T
© Copyright 2010-2020 ABB. All rights reserved.
5 Maintenance
5.6.1 Lubricating the current collector