3 Maintenance
3.3.8. Inspection, cable harness
3HAC022033-001 Revision: E
160
©
Co
py
rig
h
t 200
4 - 20
08 ABB.
All r
ig
h
ts r
e
se
rv
ed
.
Inspection, cable harness 1-4
The procedure below details how to inspect the cable harness of axes 1-4.
Location of cabling axes 5-6
The robot cable harness, axes 5-6, is located as shown in the figure below.
xx0200000155
Action
Note
1.
DANGER!
Turn off all electric power, hydraulic and
pneumatic pressure supplies to the robot!
For Foundry Prime robots: Do not turn off the
air pressure to motors and SMB.
2. Make an overall visual inspection of the cable
harness, in order to detect wear and damage.
3. Check the
connectors at the division point and
at the base.
Shown in the figure
4.
NOTE!
If the robot is used in a Foundry Prime appli-
cation, check the
cables
for cracks in
insulation.
5. Check that
velcro straps and the mounting
plate
are properly attached to the frame. Also
check the cabling, leading into the lower arm.
Make sure it is attached by the straps and not
damaged.
Location is shown in the figure
of cable harness, axes 1-4 on page 159
.
A certain wear of the hose at the
entrance to the lower arm is natural.
6. Replace the cable harness if wear, cracks or
damage is detected.
Detailed in section
Replacement of
cable harness, axes 1-6
.
A
Cable attachment, upper arm tube
B
Cable attachment, rear of upper arm
C
Connectors at cable harness division point, R2.M5/6
Continued