3.4.2 Changing oil, axis-1 gearbox
Two alternative ways of draining the oil
There are two alternatives for draining the oil on an IRB 6700Inv, inverted or floor
standing. The first section below describes inverted oil drainage and the second
floor standing oil drainage.
CAUTION
Because of the risk of getting air bubbles into axis-1 gear in inverted position, it
is recommended to let the oil be circulated through the gear, and not drained.
Usage of oil dispenser
The oil change procedure in this section describes usage of an oil dispenser.
Location of oil plugs
The oil plugs of the gearbox is located as shown in the figure.
xx1600002030
Oil plug, Tightening torque: 24 Nm
A, B
Used for both filling, ventilation and level measurement.
Continues on next page
144
Product manual - IRB 6700Inv
3HAC058254-001 Revision: L
© Copyright 2017 - 2020 ABB. All rights reserved.
3 Maintenance
3.4.2 Changing oil, axis-1 gearbox
Summary of Contents for IRB 6700I
Page 1: ...ROBOTICS Product manual IRB 6700Inv ...
Page 16: ...This page is intentionally left blank ...
Page 40: ...This page is intentionally left blank ...
Page 182: ...This page is intentionally left blank ...
Page 672: ...This page is intentionally left blank ...
Page 704: ...This page is intentionally left blank ...
Page 720: ...This page is intentionally left blank ...
Page 722: ...This page is intentionally left blank ...
Page 729: ......