4 Repair
4.7.3. Replacement of gearbox, axis 3
381
3HAC026876-001 Revision: F
© Copyri
ght
200
7-2010 ABB.
All rights reserved.
8. Fit the gearbox onto the guide
pins and slide it into position.
Make sure the o-rings are seated properly and the
gearbox correctly oriented!
9. Remove the lifting tool.
10. Secure the gearbox with 22 of
the 24 gearbox attachment
screws.
Remove the guide pins and
tighten the remaining two
screws.
24 pcs: M12 x 60.
Tightening torque: 115 Nm.
Reused screws may be used, providing they are
lubricated as detailed in the section
before fitting.
11. Refit the upper arm with a new
sealing, axis 2/3 .
Art. no. is specified in
.
Detailed in section
Refitting, upper arm on page 275
.
12. Refit the motor.
Detailed in section
.
13. Recalibrate the robot!
Calibration is detailed in a separate calibration
manual enclosed with the calibration tools.
General calibration information is included in the
section
Calibration information
.
14.
DANGER!
Make sure all safety require-
ments are met when performing
the first test run. These are
further detailed in the section
DANGER - First test run may
cause injury or damage! on
page 41
.
Action
Note
Continued