5.5 Axes 3 and 4
5.5.1 Replacing the arm house cover including the axis-4 cassette sealing
Location of the arm house cover and cassette sealing
The arm house cover including the cassette sealing is located as shown in the
figure.
xx2100001241
Summary of the replacement procedure
This is a brief summary of the replacement procedure, containing the major actions
to be performed.
1
Protection type Foundry Plus
: Remove the cover.
2 Remove the cable harness from the upper arm.
3 Remove the cable guide.
4 Replace the arm house cover including the cassette sealing.
Required spare parts
Note
The spare part numbers that are listed in the table can be out of date. See the
latest spare parts of the IRB 5720 via myABB Business Portal,
.
Level
Note
Article number
Spare part
L2
3HAC073375-003
(Graphite White)
3HAC070735-004
(ABB Orange)
Arm house cover including cas-
sette sealing
Required service parts
Note
Article number
Consumable
Shell Gadus S2
3HAC042536-001
Grease
Loctite 2400
3HAC041807-004
Locking liquid
Continues on next page
Product manual - IRB 5720
213
3HAC079195-001 Revision: A
© Copyright 2022 ABB. All rights reserved.
5 Repair
5.5.1 Replacing the arm house cover including the axis-4 cassette sealing
Summary of Contents for IRB 5720
Page 1: ...ROBOTICS Product manual IRB 5720 ...
Page 8: ...This page is intentionally left blank ...
Page 14: ...This page is intentionally left blank ...
Page 36: ...This page is intentionally left blank ...
Page 186: ...This page is intentionally left blank ...
Page 580: ...This page is intentionally left blank ...
Page 604: ...This page is intentionally left blank ...
Page 609: ......