3.7.5 Reading the SIS output logs
General
Whenever a set condition has expired (e.g. max allowed operation time before
service), a message to this effect will be shown in the Operational log.
Access to logs
How to open a log and show its contents is detailed in the User's Guide, chapter
Service
.
Available messages
The following messages may be shown:
Meaning:
SIS message in the
log:
Available in:
The manually set calendar time limit has expired.
How to set the limit is detailed in section
the SIS parameters on page 132
Service Message
Service is due!
X calendar days
since last service.
Calendar time
Proceed with the required service as detailed in
chapter
or chapter
depending on which type of service.
X number of calendar days remain until the
manually set calendar time limit expires.
Service Message
X calendar days to
next service.
Calendar time
How to set the value determining when the mes-
sage is to be shown, is detailed in section
the SIS parameters on page 132
The manually set operation time limit has expired.
How to set the limit is detailed in section
the SIS parameters on page 132
Service Message
Service is due!
X production hours
since last service.
Operation time
Proceed with the required service as detailed in
chapter
or chapter
depending on which type of service.
X number of operation hours remain until the
manually set operation time limit expires.
Service Message
X production hours
to next service.
Operation time
How to set the value determining when the mes-
sage is to be shown, is detailed in section
the SIS parameters on page 132
The automatically calculated gearbox time limit
has expired.
Service Message
Gearbox x requires
service!
Gearbox time
Proceed with the required service as detailed in
chapter
or chapter
depending on which type of service.
X percent of gearbox hours remain until the auto-
matically calculated gearbox time limit expires.
Service Message
X% of the service in-
terval has expired for
gearbox x!
Gearbox time
How to set the value determining when the mes-
sage is to be shown, is detailed in section
the SIS parameters on page 132
Product manual - IRB 4400
133
3HAC022032-001 Revision: Q
© Copyright 2004-2018 ABB. All rights reserved.
3 Maintenance
3.7.5 Reading the SIS output logs
Summary of Contents for IRB 4400/60
Page 1: ...ROBOTICS Product manual IRB 4400 ...
Page 8: ...This page is intentionally left blank ...
Page 94: ...This page is intentionally left blank ...
Page 282: ...This page is intentionally left blank ...
Page 294: ...This page is intentionally left blank ...
Page 296: ...This page is intentionally left blank ...
Page 302: ......
Page 303: ......