4 Repair
4.4.3. Replacement of complete upper arm
103
3HAC022031-001 Revision: C
©
Co
py
rig
h
t 200
4-
200
8 ABB. All righ
ts reser
v
ed.
Upper arm attachment
xx0200000436
Removal, upper arm
The procedure below details how to remove the complete upper arm.
A
Cover
B
KM nuts
C
Attachment screw
D
Sealing (insert a strap under the sealing to let the air go out when fitting the cover)
Action
Note/Illustration
1.
DANGER!
Turn off all electric power, hydraulic and pneumatic
pressure supplies to the robot!
2. Remove the tie rod.
Detailed in section
3. Loosen the connectors of the motors of axes 4, 5
and 6.
Detailed in section
motors, axes 4-6, IRB 2400L on
page 137
4. Disconnect the connection box from the motors.
5. Remove the covers (Left + Right).
6. Undo the KM nuts (Left + Right).
7. Remove the attachment screws (Left + Right).