Note
Art. no.
Equipment
See
Gasket, base cover
Fitted to the push button unit
in order to align it correctly.
3HAC025815-001
Centering piece
Replace if damaged.
Content is defined in section
.
-
Standard toolkit
See chapter
.
-
Circuit diagram
CAUTION
Always cut the paint with a knife and grind the paint edge when disassembling
parts. See
Cut the paint or surface on the robot before replacing parts on page 159
.
Removing the serial measurement unit
Use this procedure remove the serial measurement unit.
Note
Action
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot work-
ing area.
1
The push button guard must be removed
to ensure a correct refitting of the push
buttons.
xx0600002744
A Push button guard
Remove the push button guard from the base.
2
Continues on next page
Product manual - IRB 1600/1660
247
3HAC026660-001 Revision: W
© Copyright 2006-2018 ABB. All rights reserved.
4 Repair
4.5.2 Replacing the serial measurement unit
Continued
Summary of Contents for IRB 1660