Notes on the instruction manual

Product manual 2TMD042100D0003

4

1

Notes on the instruction manual

Please read through this manual carefully and observe the information it contains. This will
assist you in preventing injuries and damage to property and ensure both reliable operation and
a long service life for the device.

Please keep this manual in a safe place. If you pass the device on, also pass on this manual
along with it. ABB accepts no liability for any failure to observe the instructions in this manual.

2

Safety

Warning

Electric voltage!
Dangerous currents flow through the body when coming into direct or indirect
contact with live components.
This can result in electric shock, burns or even death.
–  Disconnect the mains power supply prior to installation and/or disassembly!
–  Permit work on the 100-240 V supply system to be performed only by

specialist staff!

3

Intended use

As part of the ABB i-HD system, this device can only be used with accessories from that system.

Summary of Contents for i-HD H81365P A Series

Page 1: ...i 2TMD042100D0003 02 12 2021 Product manual ABB i HD H81365P A Mini video outdoor station ...

Page 2: ...7 2 5 Cavity wall installation 15 8 Commissioning 16 8 1 Configure the settings on indoor station 16 8 1 1 Outdoor station enters engineering mode 16 8 1 2 Indoor station enters engineering settings 17 8 1 3 Local device settings 18 8 1 4 Lock management 20 8 1 5 Door status detection 21 8 1 6 Sound setting 22 8 1 7 Anti flicker setting 23 8 1 8 Card mode 24 8 1 9 Set the function of pushbutton 25...

Page 3: ...Table of contents Product manual 2TMD042100D0003 3 9 3 Deployment guideline 36 9 4 Upgrading 36 9 5 Backup Restore 36 9 6 Malware prevention solution 36 10 Notice 37 ...

Page 4: ...on also pass on this manual along with it ABB accepts no liability for any failure to observe the instructions in this manual 2 Safety Warning Electric voltage Dangerous currents flow through the body when coming into direct or indirect contact with live components This can result in electric shock burns or even death Disconnect the mains power supply prior to installation and or disassembly Permi...

Page 5: ...y 4 1 ABB devices All packaging materials and devices from ABB bear the markings and test seals for proper disposal Always dispose of the packing materials and electric devices and their components via an authorized collection facility or disposal company ABB products meet the legal requirements in particular the laws governing electronic and electrical devices and the REACH ordinance EU Directive...

Page 6: ... 1 Device type Article number Product ID Product name Colour Size HxWxD Unit mm H81365P1 A 2TMA130011A0001 Mini video outdoor station 1 button IC FM Aluminum alloy 105 x 180 x 43 H81365P2 A 2TMA130011A0002 Mini video outdoor station 2 buttons IC FM Aluminum alloy 105 x 180 x 43 ...

Page 7: ...7 5 2 Control elements No Description 1 Ring Indicator Indicator flashes slowly ringing Indicator flashes quickly busy line 2 Call indicator 3 Unlock indicator 4 Speaker and microphone integration 5 Round pushbutton module with IC card reader 4 5 1 2 3 ...

Page 8: ... Connector for the sensor used for door status detection 2 Connector for exit button 3 Plug in clamps LOCK AGND for door opener 4 Plug in clamps COM NC NO for floating output 5 Plug in clamps DC GND for standalone power supply 6 LAN PoE 7 N A DS NC COM NO GND DC LAN 1 2 3 4 5 6 7 LOCK AGND EXIT ...

Page 9: ... to open 12 V Type A B Electrical strike lock 24V Power on to open 24 V Type B Electrical rim lock 12 V Power on to open 12 V Type A B Electrical mortise lock Power off to open 12 V Type C Magnetic lock Power off to open 12 24 V Type C AGND GND NO DC NC DS LOCK COM EXIT AGND GND NO DC NC DS LOCK COM EXIT AGND GND NO DC NC DS LOCK COM EXIT PS PS Type A Type B Type C ...

Page 10: ...ating voltage range 20 27 V Rating current 27 V 310 mA 24 V 350 mA Operating temperature 40 C 55 C Product dimensions 105 x 180 43 mm Camera type CMOS Camera viewing angle 104 Power supply for door opener 15 V 4A impulse max 250 mA holding Floating output for door opener 30 V 3 A IP level IP 54 IK level IK 07 ...

Page 11: ...edge and experience Incorrect installation endangers your life and that of the user of the electrical system Incorrect installation can cause serious damage to property e g due to fire The minimum necessary expert knowledge and requirements for the installation are as follows Apply the five safety rules DIN VDE 0105 EN 50110 1 Disconnect 2 Secure against being re connected 3 Ensure there is no vol...

Page 12: ...Mounting Installation Product manual 2TMD042100D0003 12 7 2 Mounting 7 2 1 Preparation Use gloves to protect yourself against cuts 7 2 2 Installation height 1 5 m 5 feet ...

Page 13: ... 7 2 3 Installation situation Note The following installation situations must be avoided without fail to ensure picture quality Direct light Direct sunlight Extremely bright picture background Highly reflective walls on the opposite side of the door station ...

Page 14: ...ct manual 2TMD042100D0003 14 7 2 4 Flush mounted installation Product dimension Flush mounted with pre installation box 105 mm 180 mm 53 mm 174 mm 99 mm 45 mm 99 mm 174 mm 3 2 1 Screw shaft 4 Screw length 25 mm Mounting screw x 4 ...

Page 15: ...ation Product manual 2TMD042100D0003 15 7 2 5 Cavity wall installation Product dimension Mounting 105 mm 180 mm 43 mm 90 mm 168 mm 92 mm 97 mm 120 mm 170 mm Screw shaft 4 Screw length 25 mm Mounting screw x 4 1 2 3 4 5 ...

Page 16: ...mode Note The mini outdoor station must be in the same network with the indoor station Please follow the steps below Power up the mini outdoor station three indicators light green After a period of time three indicators light down Hold the first pushbutton for 5 s When three indicators flash green the mini outdoor station enters the engineering mode ...

Page 17: ...ers engineering settings On the extra screen of indoor station click System to access the corresponding screen On the System settings screen click Engineering settings enter the engineering password and then click Outdoor station settings to access the corresponding screen ...

Page 18: ...oduct manual 2TMD042100D0003 18 8 1 3 Local device settings On the Outdoor station settings screen select the device type 2nd OS 1 Location Internal With this setting 2nd OS is connected to the router in the apartment ...

Page 19: ...oduct manual 2TMD042100D0003 19 2 Location External With this setting 2nd OS is connected to the switch outside the apartment Note The external and internal types cannot be used in mixed scenarios in the same apartment ...

Page 20: ...reen No Function 1 Unlock type when swiping Set the lock to be released when swiping Default lock default Subsidiary lock 2 Lock type Set the lock type for the default lock and subsidiary lock Lock GND NO NC COM IP actuator 3 Time of unlock Set the time for unlock Power lock Lock GND Signal lock NO NC COM ...

Page 21: ...n If this function is enable the outdoor station will send an alarm to the management software if the door is open longer than 120 s A sensor should first be connected to the outdoor station 2 Tamper proof alarm If this function is enabled the outdoor station will send an alarm to the management software if the outdoor station is removed from the wall ...

Page 22: ...ume of outdoor station Click or to adjust the ringtone volume and the voice volume on the outdoor station 2 Button tone Tick the checkbox to enable button tones on the outdoor station 3 Voice prompt Tick the checkbox to enable voice prompts on the outdoor station Choose the language for the voice prompts from the drop down list ...

Page 23: ...Commissioning Product manual 2TMD042100D0003 23 8 1 7 Anti flicker setting On the Outdoor station settings screen select the refresh rate from the drop down list ...

Page 24: ...t manual 2TMD042100D0003 24 8 1 8 Card mode On the Outdoor station settings screen tick untick the checkbox to enable disable the function When the Safe mode is enabled ID card will not be supported by this outdoor station ...

Page 25: ...MD042100D0003 25 8 1 9 Set the function of pushbutton On the Outdoor station settings screen click Pushbutton address setting to access the settings of the pushbuttons Note Device no should be entered if Phone guard unit is selected ...

Page 26: ...6 8 1 10 Time sync setting On the Outdoor station settings screen If Sync time with management is selected the outdoor station will sync the time from the management software If Close time sync is selected the time and date needs to be set manually ...

Page 27: ...Commissioning Product manual 2TMD042100D0003 27 8 1 11 Compatible mode setting On the Outdoor station settings screen the outdoor station is set to Security mode by default Compatible mode off ...

Page 28: ...the firmware Note The outdoor station doesn t need to enter engineering mode when you want to upgrade the firmware On the Outdoor station settings screen click Firmware update select the outdoor station and the file from SD card then click OK to update the firmware ...

Page 29: ...Commissioning Product manual 2TMD042100D0003 29 8 1 13 Viewing the version On the Outdoor station settings screen view the version information ...

Page 30: ...Commissioning Product manual 2TMD042100D0003 30 8 1 14 Serial number On the Outdoor station settings screen view the serial number this number is used to get the signature from the management software ...

Page 31: ...Commissioning Product manual 2TMD042100D0003 31 8 1 15 Signature On the Outdoor station settings screen view the signature ...

Page 32: ...Commissioning Product manual 2TMD042100D0003 32 8 2 Configure the settings on PC management software Please see the product manual of ABB i HD management software for more details ...

Page 33: ...r Create admin card Swipe card 1x Green Enter settings Swipe admin card 1x Orange After entering settings following functionalities can be implemented Function Action Unlock indicator Enroll user Swipe admin card 1x Orange flash 1x Swipe user card 1x Green Delete user Swipe admin card 2x Orange flash 2x Swipe user card 1x Green Enroll new admin Swipe admin card 3x Orange flash 3x Swipe new admin c...

Page 34: ...ss and hold the 1st button for 3 s to enter configuration mode 3 LED flash green Press and hold the 1st button for 10 s to reset to factory default 3 LED OFF Reboot the device Door open LED red green orange cycle flash Technical data of IC card Work frequency Standard 13 56 MHz Mifare one S50 S70 Mifare desfire EV1 EV2 Note A maximum of 64 IC cards can be supported by mini outdoor station 2 Card m...

Page 35: ...es related to such security breaches unauthorized access interference intrusion leakage and or theft of data or information Although ABB provides functionality testing on the products and updates that we release you should institute your own testing program for any product updates or other major system updates to include but not limited to code changes configuration file changes third party softwa...

Page 36: ... decide to remove the device from system user shall reset the device to factory setting in order to remove all the configuration data and sensitive data in the device This will prevent sensitive data leak It is recommended to apply MAC filter and Rate limiter in the switch to prevent DOS attack 9 4 Upgrading Device supports firmware updates via management software a signature file will be used to ...

Page 37: ...ed specifications agreed to at the time of ordering apply to all orders ABB accepts no responsibility for possible errors or incompleteness in this document We reserve all rights to this document and the topics and illustrations contained therein The document and its contents or excerpts thereof must not be reproduced transmitted or reused by third parties without prior written consent by ABB ...

Page 38: ...nt We reserve all rights to this document and the topics and illustrations contained therein The document and its contents or extracts thereof must not be reproduced transmitted or reused by third parties without prior written consent by ABB ABB Xiamen Smart Technology Co Ltd No 881 FangShanXiEr Road Xiang An Industrial Area Torch Hi Tech Industrial Development Zone Xiamen Tel 86 592 295 9000 Fax ...

Reviews: