3. Using screws (90196) and washers (90198), fasten lifting device (90190 / 90195) to com-
pressor casing (72000) and secure to crane.
4. Position the compressor casing (72000).
Tighten nuts (61037) crosswise.
5. Remove lifting device (90190 / 90195).
6. Tighten the three press-off nuts (61090) against compressor casing (72000) by applying
the corresponding tightening torque.
Installing diffuser
Fig. 55: Installing diffuser
Product
Size
Tightening torque [Nm]
A170-M
M5
6
A175-M
M6
10
Table 45: Tightening torque (77015)
1. Loop around diffuser (79000) with lifting gear and position it on the wall insert (77000).
2. Attach diffuser with screws (77015).
3. Grease the new O-ring (77040) and fit it.