Operation Manual / TPS44-F.. - TPS61-F..
Mothballing the turbocharger
10
Taking the engine out of operation for
up to 12 months
10.1
Page 120
© Copyright 2016 ABB. All rights reserved.
A
ug
us
t2
01
7
H
ZT
L2
41
2_
E
N
R
ev
is
io
n
F
If the total acid number (TAN) is greater than 2 mg KOH/g, the following
mothballing measures are necessary after taking an engine out of operation:
τ
Dismantle the turbocharger.
τ
The rotor and the bearing parts must be removed by an official ABB
Turbocharging service station and refitted afterwards.
τ
Clean all parts.
τ
Machined, bright surfaces of steel and cast parts must be oiled with
anticorrosive oil.
τ
Reassemble complete turbocharger.
Rotor turning in stack draught
If the rotor turns as a result of the stack draught:
τ
Install blind flange between compressor casing outlet flange and
charge air duct.