8.18
Installing the gas outlet flange
Fig. 54: Installing the gas outlet flange
1. If present: Insert the metal C-ring (57003) into the turbine casing (51000) and secure with
high-vacuum grease.
2. Install the gas outlet flange (57002) in the turbine casing.
3. Measure radial clearance (R) (see chapter Radial clearances N and R).
Page
95
/
114