![ABB HT583236 Operation Manual Download Page 55](http://html1.mh-extra.com/html/abb/ht583236/ht583236_operation-manual_4177197055.webp)
Operation Manual / TPL76-C
5 Maintenance / 5.3 Cleaning the compressor during operation
© Copyright 2018 . All rights reserved.
HZTL2485_EN
Revision F
April 2018
5.3.2
Wet cleaning using external water-pressure vessel
(XC3)
Operating state prerequisites for compressor cleaning with XC3
In order to carry out a successful cleaning procedure that has been
tested and is recommended by ABB Turbo Systems, the following pre-
requisite must be met:
w
Engine load 50 ... 85%
u
Start cleaning cycle according to following description
Wet cleaning
operation with XC3.
Operating procedure for compressor wet cleaning with XC3
Operating the water pres-
sure vessel
u
The operating state prerequisites for compressor cleaning with XC3
must be fulfilled.
u
Remove sealing plug (X).
u
Fill vessel with required volume of clean water (see
table Cleaning
parameters
).
u
Screw in sealing plug (X).
u
Push the valve activator (Y) against the spring and hold it for 10 ... 15
seconds until the entire volume of water has been injected.
Page
53
/
133