
Operation Manual / 4 Product description / A130-H.. - A140-H..
5
Operation and service
Page 42 / 115
© Copyright 2015 ABB. All rights reserved.
HZTL4030_EN
Revision C
September 2015
Influencing parameters
The specified values are guideline values and are not guaranteed. The actual values can
deviate considerably from the guideline values, for example, due to the following influences:
Fuel quality and fuel treatment
Load profile (thermal cycling, also number of starts/stops, emergency shutdowns,
operating point)
Gas inlet temperature
Frequency and execution of turbine and compressor cleaning
Turbocharger specification.
System-specific operating conditions (combustion quality, exhaust gas composition)
For bearing parts
Lubricating oil quality (oil filtering, oil condition, oil monitoring)
Load profile (speed, pressure conditions, temperature)
Number of starts/stops
Imbalance of the rotor (degree of contamination).