Disassembling and assembling
turbocharger
8.3
Page 103
© Copyright 2016 ABB. All rights reserved.
Sept
em
ber
2016
H
ZT
L2412_
EN
R
ev
is
ion
F
NOTICE
To ensure the nozzle ring is held in place during operation, it must be
clamped between the partition wall and the turbine casing.
Calculate the press fit (PD) as shown.
NOTICE
If the calculated value (PD) is less than 0.1 mm, an official ABB Turbo-
charging Service Station must be contacted.
Measure the axial and radial clearances (see the section Axial and ra-
dial clearances).
Nozzle ring press fit for