Operation Manual / TPS44-F.. - TPS61-F..
Removal and installation
7
Installing the turbocharger
7.4
Page 88
© Copyright 2016 ABB. All rights reserved.
Sept
em
ber
2016
H
ZT
L2412_
EN
R
ev
is
ion
F
Installing the turbocharger
7.4
Remove covers from oil connections.
Visually inspect O-ring gaskets of oil supply and drain pipe (O-ring
gaskets for engine are not delivered by ABB Turbo Systems).
**) When the turbocharger is mounted on the engine support, the bolt
threads and screw heads must be lightly oiled (assumed friction coeffi-
cient µ = 0.12 for tightening torque)
Product
Through hole in
bearing casing
[mm]
Thread size
[mm]
Tightening
torque
[Nm]
Strength class
in acc. with
DIN/ISO 898
TPS44
17
M16
230
10.9/12.9
TPS48
17
M16
230
10.9/12.9
TPS52
21
M20
455
10.9/12.9
TPS57
21
M20
455
10.9/12.9
TPS61
25
M24
780
10.9/12.9
Attach lifting gear to bearing casing.
If a gas outlet manifold is provided, sling lifting gear around it addition-
ally or fasten it to lifting gear using a swivel lifting eye (C) (see also
section Transport / Weights).
Lift turbocharger, place on bracket and align.
Tighten fixing screws (D) to the bearing casing in accordance with the
table above.
Fasten all gas, water and air lines in accordance with the enginebuild-
er's instructions.
7.4