background image

Cyber security

Product manual 2TMD041800D0014

28

11 

Cyber security

11.1

Disclaimer

H8138.K-. products are designed to be connected and to communicate information and data via
a network interface, which should be connected to a secure network. It is customer‘s sole
responsibility to provide and continuously ensure a secure connection between the product and
customer‘s network or any other network (as the case may be) and to establish and maintain
appropriate measures (such as but not limited to the installation of firewalls, application of
authentication measures, encryption of data, installation of antivirus programs, etc.) to protect
the H8138.K-. product, the network, its system and interfaces against any kind of security
breaches, unauthorized access, interference, intrusion, leakage and/or theft of data or
information. ABB Ltd and its affiliates are not liable for damages and/or losses related to such
security breaches, unauthorized access, interference, intrusion, leakage and/or theft of data or
information.

Although ABB provides functionality testing on the products and updates that we release, you
should institute your own testing program for any product updates or other major system
updates (to include but not limited to code changes, configuration file changes, third party
software updates or patches, hardware change out, etc.) to ensure that the security measures
that you have implemented have not been compromised and system functionality in your
environment is as expected.

11.2

Performance and service

Network performance

Type

Value

Ethernet

24 Mbps (37,449 packets/sec)

ARP

12 Mbps (18,724 packets/sec)

ICMP

22 Mbps (34,328 packets/sec)

IP

22 Mbps (34,328 packets/sec)

Port and service

Port

Service

Purpose

5070

UDP

To be used by SIP client.

7777

TCP/UDP

To be used for device management.

10777

TLS

Secure channel for device management

7005

TCP

To be used for connectivity detection when this feature is enabled.

8887

TCP

To be used for firmware update.

Summary of Contents for H8138.K Series

Page 1: ...2TMD041800D0014 22 07 2019 Product manual ABB Welcome IP H8138 K IP keypad outdoor station H8138 K 02 IP keypad outdoor station ...

Page 2: ...ty wall installation 16 8 Commissioning 18 8 1 Accessing the Menu screen 18 8 2 Engineering settings 19 8 2 1 Engineering settings overview 19 8 3 Access control settings 20 8 3 1 Access control overview 20 8 4 System settings 21 8 4 1 System settings overview 21 8 5 Logical address setting 23 9 Operation 24 9 1 Calling a resident 24 9 2 Calling a guard unit 24 9 3 Releasing the lock 25 9 3 1 Rele...

Page 3: ...Table of contents Product manual 2TMD041800D0014 3 11 3 Deployment guideline 29 11 4 Upgrading 29 11 5 Backup Restore 29 11 6 Malware prevention solution 29 11 7 Password rule 29 ...

Page 4: ...ep this manual in a safe place If you pass the device on also pass on this manual along with it ABB accepts no liability for any failure to observe the instructions in this manual 2 Safety Warning Electric voltage Dangerous currents flow through the body when coming into direct or indirect contact with live components This can result in electric shock burns or even death Disconnect the mains power...

Page 5: ...ires a certificate issued by the management software before it can function normally Compatible mode If there is no management software this outdoor station needs to run in Compatible mode to function normally It can be set on indoor station Please refer to the product manual for IP touch 7 Video privacy Video privacy Making and saving video recordings can infringe on personal rights Always observ...

Page 6: ...Intended use Product manual 2TMD041800D0014 6 Application Switch IP keypad OS Guard unit IP touch 7 WipAP Functional LAN mode Community Home IP actuator ...

Page 7: ...y 4 1 ABB devices All packaging materials and devices from ABB bear the markings and test seals for proper disposal Always dispose of the packing materials and electric devices and their components via an authorized collection facility or disposal company ABB products meet the legal requirements in particular the laws governing electronic and electrical devices and the REACH ordinance EU Directive...

Page 8: ...cription Product manual 2TMD041800D0014 8 5 Product description 5 1 Control elements No Function 1 Camera 2 Speaker and microphone integration 3 Display module with ID IC card reader 4 Keypad 5 End strip 1 2 3 4 5 ...

Page 9: ...for door opener 5 Plug in clamps COM NC NO for floating output door opener 6 LAN PoE 7 Connector for next module 8 Connector for exit button 9 Connector for the sensor used for door status detection 10 Connector for 5 display module 11 Connector for previous module 12 Connector for Wiegand output It supports 26 bits and 34 bits 13 Connector for device software updating 2 7 7 11 12 13 11 13 1 2 3 4...

Page 10: ...ower on to open 12 VDC AC Type A Type B Electrical strike lock 24V Power on to open 24 VDC AC Type B Electrical rim lock 12 V Power on to open 12 VDC Type A Type B Electrical mortise lock Power off to open 12 VDC Type C Magnetic lock Power off to open 12 24 V DC Type C GND NO DC NC LOCK COM GND NO DC NC LOCK COM GND NO DC NC LOCK COM PS PS Type A Type B Type C ...

Page 11: ...ct dimensions 135 mm x 348 9 mm x 17 6 mm Display type LCD Display size 57 8 mm 31 9 mm Camera type CMOS Camera viewing angle 130 Resolution ratio HD 1280 x 720 pixel Power supply for door opener 18 V 4A impulse max 250 mA holding Floating output for door opener 230 V AC 3 A 30 V DC 3 A Video codec H 264 Audio codec G 711 IP level IP54 IK level IK07 Network connection standard IEEE 802 3 10Base T ...

Page 12: ...edge and experience Incorrect installation endangers your life and that of the user of the electrical system Incorrect installation can cause serious damage to property e g due to fire The minimum necessary expert knowledge and requirements for the installation are as follows Apply the five safety rules DIN VDE 0105 EN 50110 1 Disconnect 2 Secure against being re connected 3 Ensure there is no vol...

Page 13: ...Mounting Installation Product manual 2TMD041800D0014 13 7 2 Mounting 7 2 1 Preparation Use gloves to protect yourself against cuts 7 2 2 Wiring ...

Page 14: ...oduct manual 2TMD041800D0014 14 7 2 3 Surface mounted installation 7 2 4 Flush mounted installation 1 Flush mounted without pre installation box 2 83 mm 40 mm 71 mm 1X4 3 4 5 6 7 8 2 1 117 mm 46 mm 336 mm 1X4 2 1 4 5 6 7 8 9 3 ...

Page 15: ...Mounting Installation Product manual 2TMD041800D0014 15 2 Flush mounted with pre installation box 5 6 7 8 9 10 4 34 6 mm 68 m m 126 m m 1X4 3 2 1 ...

Page 16: ...Mounting Installation Product manual 2TMD041800D0014 16 7 2 5 Cavity wall installation 1 2 3 5 6 7 8 6 4 5 10 9 ...

Page 17: ...lation situations Note The following installation situations must be avoided without fail to ensure picture quality Direct light Direct sunlight Extremely bright picture background Highly reflective walls on the opposite side of the door station Lamps or direct light sources ...

Page 18: ...ing work and should be changed to another password It cannot be used as the actual password Note If an incorrect system password is entered 10 times within 5 minutes no further attempts are permitted for the next 5 minutes Password rule The password must not include continuously increasing or decreasing numbers e g 123456 654321 and three consecutive identical numbers are similarly not permitted e...

Page 19: ...tion 01 64 Gate station 01 32 System attribute IS digits 3 digits 4 digits default Block no outdoor station 001 999 Block digits gate station 1 digit 2 digits 3 digits Default GU 01 32 Digits of indoor station 3 digits 4 digits Change system password Input new password 1 Mode select Compatible mode Security mode Call mode Physical address Logical address 1 Mode select This outdoor station is used ...

Page 20: ...assword is used by everyone for access via the entrance It is set on the local outdoor station 2 Private password This password is used by each resident for access via the entrance It is set on indoor station Please see the product manual for IP touch 7 for more details Password rule The password must not include continuously increasing or decreasing numbers e g 123456 654321 and three consecutive...

Page 21: ...ault On Ringtone volume Off Low Medium default High Date and time Local setting Date and time setting Management software sync Language Wiegand settings Off default 26 bits 34 bits Choose door Default lock L1 LOCK GND L2 NO NC COM IPA LOVK GND 1 32 IPA NO NC COM 1 32 Auxiliary lock L1 LOCK GND L2 NO NC COM IPA LOVK GND 1 32 IPA NO NC COM 1 32 1 Voice prompt If this function is enabled the outdoor ...

Page 22: ...On alarm sound Temper alarm Off default On Call forward to guard unit Off default On Lift settings Enable lift Off default On Floor no outdoor station 7 63 2 Block no 001 999 Anti flicker 50 Hz 60 Hz default Reset factory default Press Help Version 2 Block no This block no means the number of the lift control module It must be the same as the number of the connecting outdoor station ...

Page 23: ...re use On the Menu screen click Logical address settings to access the corresponding screen Add Enter Logical address Physical address to add a new one Modify Enter Logical address then enter new Logical address Physical address to change it Delete Enter Logical address to delete it Clear all Enter to clear all logical address ...

Page 24: ...room no e g 0101 press to end the call 2 Device type GS In standby mode enter the building no room no e g 020101 press to end the call Forward to GU If Call forward is enabled all calls will be transferred to the guard unit 9 2 Calling a guard unit In standby mode press to call the default guard unit Press to end the call ...

Page 25: ... details Swipe registered ID IC cards near the area see diagram below to release the lock ID card specification Operating frequency 13 56 MHz Standard ISO 14443A Support card EM4100 EM4205 EM4305 EM4450 TK4100 T5567 T5577 Output format Wiegand 26 34 bit IC card specification Operating frequency 125 KHz Standard ISO 18000 2 Support card Mifare one S50 S70 Mifare desfire EV1 EV2 Output format Wiegan...

Page 26: ...Releasing the lock by entering the private password The private password must be enabled before use Please see the Access control overview chapter for more details In standby mode 1 Device type Outdoor station Release default lock 1 room no private password Release auxiliary lock 2 room no private password 2 Device type Gate station Release default lock 1 building no room no private password Relea...

Page 27: ...esigned to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment ...

Page 28: ... or losses related to such security breaches unauthorized access interference intrusion leakage and or theft of data or information Although ABB provides functionality testing on the products and updates that we release you should institute your own testing program for any product updates or other major system updates to include but not limited to code changes configuration file changes third part...

Page 29: ...vice This will prevent sensitive data leak It is recommended to apply MAC filter and Rate limiter in the switch to prevent DOS attack 11 4 Upgrading Device supports firmware updates via management software a signature file will be used to verify the authentication and integrity of firmware 11 5 Backup Restore None 11 6 Malware prevention solution The H8138 K device is not susceptible to malware be...

Page 30: ...d specifications agreed to at the time of ordering apply to all orders ABB accepts no responsibility for possible errors or incompleteness in this document We reserve all rights to this document and the topics and illustrations contained therein The document and its contents or excerpts thereof must not be reproduced transmitted or reused by third parties without prior written consent by ABB ...

Page 31: ...anayi Bolgesi 2 Cadde No 16 Y Dudullu Istanbul T 90 216 528 2281 F 90 216 528 2945 ABB KSA Electrical Industries Co Ltd P O Box 325841 Riyadh 11371 T 966 1 1484 5600 F 966 1 1206 7609 ABB Thailand Ltd 161 1 SG Tower 1st 4th Floor Soi Mahadlekluang 3 Rajdamri Road Lumpini Pathumwan Bangkok 10330 Thailand T 66 2 6651 000 F 66 2 6651 043 ABB Russia Ltd 3121 Wiring Accessories 30 1 bld 2 Obrucheva str...

Page 32: ...Error Use the Home tab to apply Überschrift 1 to the text that you want to appear here Product manual 2TMD041800D0014 32 Copyright 2019 ABB All rights reserved ...

Reviews: