background image

Product description

Operating Instructions VER:1.0

10

Pos: 33 /CNDEX/01 Heading/1.1 Heading/Heading_Lock type and connection @ 56\mod_1487747624072_15.docx @ 750093 @ 2 @ 1

5.4

Lock type and connection

Pos: 34 /CNDEX/05 Terminal description/Lock type_OS @ 56\mod_1487645786193_15.docx @ 748070 @  @ 1

Lock type

Operation type

Voltage

Wiring type

Electrical strike lock, 12
V

Power on to open

12 VDC/AC

Type A
Type B

Electrical strike lock, 24
V

Power on to open

24 VDC/AC

Type B

Electrical rim lock, 12 V

Power on to open

12 VDC

Type A
Type B

Electrical mortise lock

Power off to open

12 VDC

Type C

Magnetic lock

Power off to open

12/24 V DC

Type C

Tab.5:  Lock 

type

Pos: 35 /CNDEX/05 Terminal description/Lock connection_H8137xPx-S_H8137xK-S_OS @ 57\mod_1488954276165_15.docx @ 759797 @  @ 1

Fig. 

5: 

Lock 

connection

Pos: 36 /CNDEX/99 Auxiliary tools/++++++++++++++  page break +++++++++++++++ @ 57\mod_1487814735946_0.docx @ 750979 @  @ 1

DC+

GND

LOCK

NC

COM

NO

DC+

GND

LOCK

NC

COM

NO

DC+

GND

LOCK

NC

COM

NO

PS

Type A

Type B

Type C

+

-

PS

+

-

Summary of Contents for H8137xPx-S

Page 1: ... Title 00_Title H8137xPx S_H8137xK S 63 mod_1500620160705_0 docx 801123 1 2TMD041700D0042 01 08 2017 Operating Instructions ABB Welcome IP Video outdoor station H8137xPx S H8137xK S Ende der Liste für Textmarke Titel ...

Page 2: ...a 11 7 Mounting Installation 12 7 1 Requirement for the electrician 12 7 2 Mounting 13 7 2 1 Flush mounted installation 14 7 2 2 Replacing the nameplate 16 7 2 3 Installation situations 17 8 Commissioning 18 8 1 Building outdoor station 18 8 1 1 Enter system setting of building OS 18 8 1 2 Engineering setting 19 8 1 3 Access control setting 21 8 1 4 System setting 23 8 2 Villa outdoor station 26 9...

Page 3: ...tage Dangerous currents flow through the body when coming into direct or indirect contact with live components This can result in electric shock burns or even death Disconnect the mains power supply prior to installation and or disassembly Permit work on the 110 240 V supply system to be performed only by specialist staff Pos 13 CNDEX 01 Heading 1 Heading Heading_Intended use 56 mod_1487743332845_...

Page 4: ...B devices 62 mod_1496803248336_15 docx 786222 2 1 4 1 ABB devices Pos 20 CNDEX 00 Warning Txt_ABB devices_Environment 56 mod_1487743585555_15 docx 749915 12 1 All packaging materials and devices from ABB bear the markings and test seals for proper disposal Always dispose of the packing materials and electric devices and their components via an authorized collection facility or disposal company ABB...

Page 5: ... Pos 25 CNDEX 03 Front overview Control elements_H8137xPx S_H8137xK S_OS 57 mod_1488952981678_15 docx 759737 1 Fig 1 Control elements No Function 1 Camera 2 White LED total 6 pcs 3 Light sensor 4 Speaker and microphone integration 5 Display module with ID IC card reader 6 Keypad 7 End strip 8 Round push button 9 Nameplate this silk screen means built in ID IC card reading function Tab 1 Descriptio...

Page 6: ...OE and directly stand alone power supply Open the door with public private password Open the door with card For building outdoor station 2 000 cards for outdoor station and 40 000 for gate station For villa outdoor station 300 cards 2 options for built in RFID proximity reader ID card or IC NFC card Support of Wiegand output to integrate with 3rd party access control system Support of 2 locks conn...

Page 7: ... power is on 3 Set button Press and hold this button for 3 s to enter configuration mode when the power is on And press and hold this button for 5 s to restore to factory setting after the power is on 4 Connector for software updating of this module 5 Connector for sensor used for door status detection 6 Connector for exit push button 7 Connector for next module 8 Plug in clamps COM NC NO for floa...

Page 8: ...iption of pushbutton module No Function 1 Program button 2 Connector for previous module 3 Connector for software updating of this module 4 Connector for Wiegand output It supports 26 bits default and 34 bits 5 Connector for next module Tab 3 Description 1 2 3 5 4 H8137xPx S ...

Page 9: ...Connector for previous module 3 Connector for software updating of this module 4 USB connector reserved 5 Connector for next module 6 Connector for Wiegand output It supports 26 bits default and 34 bits Tab 4 Description Pos 32 CNDEX 99 Auxiliary tools page break 57 mod_1487814735946_0 docx 750979 1 1 2 3 5 6 4 SET BOO T 1 2 3 5 4 H8137xK S ...

Page 10: ...DC AC Type A Type B Electrical strike lock 24 V Power on to open 24 VDC AC Type B Electrical rim lock 12 V Power on to open 12 VDC Type A Type B Electrical mortise lock Power off to open 12 VDC Type C Magnetic lock Power off to open 12 24 V DC Type C Tab 5 Lock type Pos 35 CNDEX 05 Terminal description Lock connection_H8137xPx S_H8137xK S_OS 57 mod_1488954276165_15 docx 759797 1 Fig 5 Lock connect...

Page 11: ...1 Designation Value Operating temperature 40 C 70 C Protection cover frame assembled dustproof and waterproof as IP 54 vandal proof as IK 07 Power supply door opener Lock GND 18 V 4 A impulsive 250 mA holding Floating supply door opener COM NC NO 30 VAC DC 1A Working voltage 27 VDC Dimension H8137xPx S 273 8 mm x 135 mm x 48 5 mm H8137xK S 346 8 mm x 135 mm x 48 5 mm Tab 6 Technical data Pos 40 CN...

Page 12: ...ctric voltage_Install the device 56 mod_1487743205578_15 docx 749810 1 Warning Electric voltage Install the device only if you have the necessary electrical engineering knowledge and experience Incorrect installation endangers your life and that of the user of the electrical system Incorrect installation can cause serious damage to property e g due to fire The minimum necessary expert knowledge an...

Page 13: ...07 Mounting Installation Preparation_OS 56 mod_1487742936063_15 docx 749767 1 Use gloves to protect yourself from being cut Fig 6 Preparation Pos 49 CNDEX 07 Mounting Installation Wiring_H8137xPx S_H8137xK S_OS 58 mod_1489113964205_15 docx 765047 1 Fig 7 Wiring Pos 50 CNDEX 99 Auxiliary tools page break 57 mod_1487814735946_0 docx 750979 1 DC GND SET BOOT LOCK COM NC NO LAN ...

Page 14: ...2 1 Flush mounted installation Pos 52 CNDEX 07 Mounting Installation Product dimension_H8137xPx S_H8137xK S_OS 57 mod_1488957202224_15 docx 759900 1 Fig 8 Product dimension Pos 53 CNDEX 99 Auxiliary tools page break 57 mod_1487814735946_0 docx 750979 1 135 mm 135 mm 48 5 mm 48 5 mm 273 8 mm 346 8 mm TOP 110 mm 41 5 mm 262 5 mm 110 mm 335 5 mm 41 5 mm H8137xPx S H8137xK S ...

Page 15: ...os 54 CNDEX 07 Mounting Installation Flush mounted installation_H8137xPx S_H8137xK S_OS 57 mod_1488957107080_15 docx 759940 1 Fig 9 Flush mounted installation Pos 55 CNDEX 99 Auxiliary tools page break 57 mod_1487814735946_0 docx 750979 1 H8137xPx S H8137xK S ...

Page 16: ...ate 56 mod_1487748988144_15 docx 750237 3 1 7 2 2 Replacing the nameplate Pos 57 CNDEX 07 Mounting Installation Replace the nameplate_H8137xPx S_Villa OS 57 mod_1488958428077_15 docx 759960 1 Fig 10 Replace the nameplate Pos 58 CNDEX 99 Auxiliary tools page break 57 mod_1487814735946_0 docx 750979 1 2 H8137xPx S 01 02 1 ...

Page 17: ... Warning Note_Installation situations 56 mod_1487743694622_15 docx 749937 1 Note The following installation situations must be avoided without fail to ensure picture quality Direct light Direct sunlight Extremely bright picture background Highly reflective walls on the opposite side of the door station Lamps or direct light sources Pos 61 CNDEX 99 Auxiliary tools page break 57 mod_1487814735946_0 ...

Page 18: ...door station Pos 65 CNDEX 01 Heading 1 1 1 Heading Heading_Enter system setting of building OS 62 mod_1496805537569_15 docx 786317 3 1 8 1 1 Enter system setting of building OS Pos 66 CNDEX 08 Commissioning Enter system setting_H8137xK S_Building OS 62 mod_1496805652119_15 docx 786338 1 Fig 11 Enter system setting On standby mode press system code to enter the system setting Default system code is...

Page 19: ...ock information If GS set block digits here if OS set block number here Fig 14 Set block information Set IS digits Fig 15 Set IS digits Engineering Device attr Device attr Device type Device type GS OS Menu Engineering Engineering Device attr OS Device attr Device No Device No 01 Input GS No 01 Menu Engineering OS GS OS GS OS GS Engineering System attr System attr Block digits Block digits 2 digit...

Page 20: ...rd Fig 17 Set system password Pos 70 CNDEX 99 Auxiliary tools page break 57 mod_1487814735946_0 docx 750979 1 Engineering System attr System attr Default GU Guard type 0 Guard No 01 0 GU 1 PC OS GS Menu Engineering Engineering System attr System attr System pwd OS GS Default pwd 345678 Menu Engineering ...

Page 21: ...etting Fig 18 Access control password setting Card mode setting Fig 19 Card mode setting User card management Fig 20 User card management Menu Access control Access control Pwd setting Pwd setting New pub pwd Pwd setting Enable pub Pwd setting Enable pvt New pwd Enable pub ON OFF Enable pvt ON OFF Card setting Card mode Card mode Customization Standard Access control Card setting Menu Access contr...

Page 22: ..._1487814735946_0 docx 750979 1 Card No Del one card Press confirm Delete one Del one card Press confirm Card setting Patrol card Patrol card Add Patrol card Unlock setting Patrol card Delete Patrol card Delete all Unlock setting ON OFF Access control Card setting Confirm Delete all cards Del one card Press confirm Menu Access control Card setting Copy Access control Card setting 02 Destn OS No Del...

Page 23: ...te and time Set languages Fig 25 Set languages Set Wiegand Fig 26 Set Wiegand Choose default lock Fig 27 Choose default lock Menu System setting System setting Volume Voice volume Medium High Low Volume Voice volume Volume Key tone Key tone ON OFF 2016 09 06 Press confirm 15 55 Menu System setting System setting Date time Menu System setting System setting Lanuage Language English 中 Menu System se...

Page 24: ...ng Unlock time Unlock time 2nd NC NO C 1st LOCK GND Menu System setting Choose door Unlock time System setting Door alarm Door alarm ON OFF Menu System setting Choose door Unlock time Door alarm System setting Tamper alarm Tamper alarm ON OFF Menu System setting Choose door Unlock time Door alarm Floor No Press confirm 01 Block No 001 System setting Lift setting Lift setting Enable lift Lift setti...

Page 25: ...CNDEX 99 Auxiliary tools page break 57 mod_1487814735946_0 docx 750979 1 Menu System setting Anti flicker Restore Press confirm System setting Restore Menu System setting System setting Help I Mx_1 14_161227 LCD_1 12_161205 KP_2 07_151116 Ext_1 05_160905 Help Guide Station no Eg 0101 1 Input Indoor Help Version Menu System setting Help System setting Forward to GU Forward to GU ON OFF ...

Page 26: ...tdoor station 58 mod_1489108711728_15 docx 764767 2 1 8 2 Villa outdoor station Pos 78 CNDEX 08 Commissioning Find details in the system manual 62 mod_1497234325447_15 docx 788858 1 Please find details in the system manual Pos 79 CNDEX 99 Auxiliary tools page break 57 mod_1487814735946_0 docx 750979 1 ...

Page 27: ...a resident Villa outdoor station H8137xPx s Press the first button to start a call Press again to end the call If there is no answer from the resident within 30 s the call ends automatically Building outdoor station H8137xK S If the device is set as OS outdoor station enter the room number and press the call button If the device is set as GS gate station enter the building number room number and p...

Page 28: ...Fig 37 Forward to GU If the device enables the function Forward to GU all the calls from the visitors will be transferred to the guard unit Pos 84 CNDEX 99 Auxiliary tools page break 57 mod_1487814735946_0 docx 750979 1 Menu System setting System setting Forward to GU Forward to GU ON OFF ...

Page 29: ...oor station H8137xPx S Press the second button to call the guard unit Press again to end the call If there is no answer from the guard unit within 30 s the call ends automatically The second button can be set as calling PC guard through the indoor station Building outdoor station H8137xK S Press to call the guard unit Press to end the call If there is no answer from the resident within 30 s the ca...

Page 30: ...c password public password Default public password is 201007 This function is disabled by default See chapter Access control setting to enable the function See product manual of indoor station to change the password Unlock by user password Device type OS room number user password Default user password is 123456 this is only used to set a new password at the first time Device type GS building numbe...

Page 31: ...tion Pos 92 CNDEX 09 Operation Manage cards by indoor station_H8137xPx S_Villa OS 58 mod_1489111576489_15 docx 764952 1 Note Please assign the outdoor station to a specific apartment first before configuring the ID IC card Fig 40 Manage ID IC cards on indoor station Press on the indoor station Click Door Entry then click Select Click Private OS and enter the 6 digit private password Default is 123...

Page 32: ...uccessful the push button module lights up green During the process of card registering or card deletion the push button module will light up or flash You can press the 1st round push button to quit the process Technical data of ID card Work frequency Standard Support ID card protocol 125KHz ISO18000 2 EM4100 EM4205 EM4305 EM4450 TK4100 T5567 T5577 Table 7 Technical data of IC card Designation Val...

Page 33: ...tion Additional devices are not required for commissioning To the play store https play goole com store apps details id com abb allegro3_nfcdooropener hl en 1 Download and install the ABB door opener app from the Google Play Store 2 Turn on the NFC function of your mobile device 3 Enter the setting mode of the round push button module 4 Start using the NFC app on your mobile device 5 Set up your m...

Page 34: ...o the contents of this document without prior notice The detailed specifications agreed to at the time of ordering apply to all orders ABB accepts no responsibility for possible errors or incompleteness in this document We reserve all rights to this document and the topics and illustrations contained therein The document and its contents or excerpts thereof must not be reproduced transmitted or re...

Page 35: ... P O Box 325841 Riyadh 11371 T 966 1 1484 5600 F 966 1 1206 7609 ABB Thailand Ltd 161 1 SG Tower 1st 4th Floor Soi Mahadlekluang 3 Rajdamri Road Lumpini Pathumwan Bangkok 10330 Thailand T 66 2 6651 000 F 66 2 6651 043 ABB Russia Ltd 3121 Wiring Accessories 30 1 bld 2 Obrucheva str RU T 7 495 777 2220 F 7 495 777 2220 ABB Korea Ltd Oksan Bldg 10th Fl 157 33 Samsung dong Gangnam gu 135 090 Seoul Kor...

Reviews: