424 Parameters
Modoff delay time
If drive modulation is lost during the SLS
deceleration ramp and the modulation does
not return within
time, FSO
activates STO.
Note:
If speed is below SLS limit (eg,
), modoff is ignored.
Monitoring active
If drive modulation is lost during the SLS
deceleration ramp, SLS ramp or time
monitoring (
) is kept on. Limit hit is
generated based on the last valid speed
estimate information of FSO.
Monitoring active
and Modoff delay
time
Both Modoff delay time and Monitoring
active values are in use: FSO generates the
hit based on whichever condition is met first
and activates the STO.
Monitoring and
modoff delay time
are disabled
If drive modulation is lost during the SLS
deceleration ramp, FSO does not activate
STO. SLS indication (eg,
) goes on
after
time has elapsed.
SLSx.06 SLS ramp modoff
delay time
Time to trip when modulation is lost.
Note:
This time must be set shorter than
, otherwise STO is not activated due
to limit hit when drive modulation is lost with
SLS function.
Note:
If encoder feedback is in use,
SLSx.06 parameter has no effect.
0 ms
0…3,600,000 ms
Time
SLSx.11 SLS1 input A
Sets the primary digital input for the SLS1
function.
None
No input connected
DI X113:1 & X114:1 Redundant input X113:1 & X114:1
DI X113:2 & X114:2 Redundant input X113:2 & X114:2
DI X113:3 & X114:3 Redundant input X113:3 & X114:3
DI X113:4 & X114:4 Redundant input X113:4 & X114:4
DI X113:1
Single input X113:1
DI X113:2
Single input X113:2
DI X113:3
Single input X113:3
DI X113:4
Single input X113:4
DI X114:1
Single input X114:1
DI X114:2
Single input X114:2
DI X114:3
Single input X114:3
DI X114:4
Single input X114:4
Index
Name/Value
Description
Factory
default
Summary of Contents for FSO-21
Page 1: ... OPTIONS FOR ABB DRIVES FSO 21 safety functions module User s manual ...
Page 4: ......
Page 16: ...16 Safety instructions ...
Page 34: ...34 Safety information and considerations ...
Page 52: ...52 Overview ...
Page 236: ...236 PROFIsafe ...
Page 265: ...PROFIsafe 265 2 Select your CPU from the list 3 Install the FENA 21 GSDML file ...
Page 275: ...PROFIsafe 275 20 In ABB_Drive FB add blocks DPRD_DAT and DPWR_DAT 21 Insert values to blocks ...
Page 282: ...282 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Page 286: ...286 PROFIsafe ...
Page 304: ...304 Installation ...
Page 400: ...400 Configuration ...
Page 488: ...488 Verification and validation ...
Page 506: ...506 Fault tracing ...
Page 514: ...514 Maintenance ...
Page 536: ...536 Technical data ...