362 Configuration
Configuring SLS
To configure the SLSn (n = 1…4), set the FSO parameters listed below to appropriate
values using the Drive composer pro PC tool. See parameter groups
on
page
on page
For more information on the SLS function, see page
.
Depending on the application, set the negative and positive SLS and SLS trip limits
separately.
How to configure SLSn with time monitoring
Example:
The figure below shows an example of the SLS1 function with time
monitoring set-up:
• SLS1 function activated (
=
Version 1
)
• time monitored deceleration ramp
SLS activation monitoring method
Time
)
• deceleration ramp according to drive parameters (always with time monitoring)
• SLS activation delay: 2000 ms (
2000 ms
)
• automatic acknowledgement (
=
Automatic
)
• redundant SLS activation button connected to input
=
DI X113:2 & X114:2
)
• single output connected (
DO X114:7
)
• positive limits: SLS 1200.0 rpm, trip limit 1320.0 rpm
=
1200 rpm,
=
1320 rpm
).
• negative limits: SLS -900.0 rpm, trip limit -1020.0 rpm
=
-900 rpm,
-1020 rpm
).
• See also section
on page
.
Note
: The difference between the SLS limit and the corresponding SLS trip limit must
be at least 0.1 rpm.
Note
: If you also use the SMS function, the SLS trip limits positive and negative must
be below the speed defined by parameter
and above the speed
defined by parameter
, respectively.
Summary of Contents for FSO-21
Page 1: ... OPTIONS FOR ABB DRIVES FSO 21 safety functions module User s manual ...
Page 4: ......
Page 16: ...16 Safety instructions ...
Page 34: ...34 Safety information and considerations ...
Page 52: ...52 Overview ...
Page 236: ...236 PROFIsafe ...
Page 265: ...PROFIsafe 265 2 Select your CPU from the list 3 Install the FENA 21 GSDML file ...
Page 275: ...PROFIsafe 275 20 In ABB_Drive FB add blocks DPRD_DAT and DPWR_DAT 21 Insert values to blocks ...
Page 282: ...282 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Page 286: ...286 PROFIsafe ...
Page 304: ...304 Installation ...
Page 400: ...400 Configuration ...
Page 488: ...488 Verification and validation ...
Page 506: ...506 Fault tracing ...
Page 514: ...514 Maintenance ...
Page 536: ...536 Technical data ...