312 Configuration
Configuring general settings
How to configure general settings
To configure the general settings, set the FSO parameters listed below to appropriate
values using the Drive composer pro PC tool. See parameter group
FSOGEN
on
page
180
.
Example:
The figure below shows an example I/O set-up:
• After power-up, the acknowledgement can only be performed manually
FSOGEN.41 Power-up acknowledgement =
Manual
).
• Acknowledgement button is connected to input X114:4
=
DI X114:4
).
•
50.00 Hz
. Use the same value with the
drive parameter
99.08. Motor nominal frequency
, and the value on the motor type
designation label.
Note:
For a DCS880 drive, set this value to
25 Hz
.
•
=
1360.0 rpm
. Use the same value with the
drive parameter
99.09 Motor nominal speed
, and the value on the motor type
designation label.
Note:
For a DCS880 drive, the equivalent parameter is
99.14
M1 nominal (base) speed
.
•
90.0 rpm
(when an encoder is used:
). Stopping
functions are considered to be completed at this speed. Use suitable (low
enough) value according to application.
• External requests ending in the drive STO are reported to the drive as events
FSOGEN.61 STO indication ext request
=
Event
).
• Safety function limit hits are reported as faults
=
Fault
).
• No output connected for the completion of stop functions (STO, SSE, SS1)
None
).
= DI X114:4
= 50.00 Hz
= 1360.0 rpm
= Manual
= Event
= Fault
Drive
event
system
= 90.0 rpm
M
= None
Summary of Contents for FSO-21
Page 1: ... OPTIONS FOR ABB DRIVES FSO 21 safety functions module User s manual ...
Page 4: ......
Page 16: ...16 Safety instructions ...
Page 34: ...34 Safety information and considerations ...
Page 52: ...52 Overview ...
Page 236: ...236 PROFIsafe ...
Page 265: ...PROFIsafe 265 2 Select your CPU from the list 3 Install the FENA 21 GSDML file ...
Page 275: ...PROFIsafe 275 20 In ABB_Drive FB add blocks DPRD_DAT and DPWR_DAT 21 Insert values to blocks ...
Page 282: ...282 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Page 286: ...286 PROFIsafe ...
Page 304: ...304 Installation ...
Page 400: ...400 Configuration ...
Page 488: ...488 Verification and validation ...
Page 506: ...506 Fault tracing ...
Page 514: ...514 Maintenance ...
Page 536: ...536 Technical data ...