I N S T A L L A T I O N P R O C E D U R E S
FOX615
Installation
43
3.4.2
Installing the DC power supply
3.4.2.1
Power cable
The power cable (refer to
) connects the external power circuit(s) to
the FOX local power interface(s). One end of the power cable is terminated
with the TYCO connector for the FOX subrack (or DUPF1). The other end is
terminated with the WAGO connector block. This connector block provides
the connection point for the external power supply.
Power cables are required as follows:
•
Single
power source supply:
1 power supply cable is required
•
Dual
power source supply:
2 power supply cables are required.
Please note:
The second power cable is delivered together with the DUPF1 in a separate
package.
Figure 23: FOX power supply cable
Legend:
1
WAGO connector block
2
TYCO connector
The WAGO connector block is mounted on the cable tray either inside the
• right
OR
left side panel of the cable tray for
single power
source sup-
plies.
• right
AND
left side panels of the cable tray for
dual power
source sup-
plies.
shows the 2 installation options.
blue
Blue (-)
Blue (-)
Red (+)
Red (+)
1
2
A
A
red