Service configuration page
On the Service configuration page, you can enable or disable certain Ethernet services.
All services except Simple Network Time Protocol (SNTP) are enabled by default. You
can disable the following services on this page:
•
access to FMBT-21 configuration web page
•
allow to change IP settings remotely via ABB IP configuration tool
•
remote access drive with Drive composer tool via Ethernet tool network
•
Ping response
•
configure SNTP.
The new settings take effect after reboot of the module. You can click Save and reboot,
to validate the new settings immediately or click Save without rebooting if you want
to do other settings also and then reboot.
Note: These settings are available only through web pages. When you select to disable
the web page, a warning appears to confirm before you can save the selection.
Or, you can use the web page password. See
Enable web page access after it was
It is recommended to disable all services that are not used after commissioning.