S P I R I T
I T
F L O W - X
I N S T R U C T I O N M A N U A L | I M / F L O W X - E N
2 9
X/P
Master meter pulses
Figure 6-33: Master meter proving based on pulses on an X/P flow
computer.
X/P
Master meter totals
Figure 6-34: Master meter proving based on totalizers on an X/P flow
computer.
Prover flow computer with remote runs
Ball prover / Compact prover
Connect the flow pulse signals to the corresponding run
modules
Connect the prover bus pulse output of the run modules to the
prover bus pulse input of the prover module
Connect all detector signals to the prover module
Connect all applicable prove signals (except the detector
signals) to the prover module:
–
prover pressure(s)
–
prover temperature(s)
–
prover densitometer
–
4-way valve commands and statuses
–
prover commands and statuses
Master meter proving based on pulses
Connect the flow pulse signals to the corresponding run
module(s) and master meter module
Connect the prover bus pulse output of the run modules to the
‘prover bus pulse input’ of the prover module
Connect a digital output of the prover module to a digital input
(prove detector in) of itself
Master meter proving based on totals
No connections to be made (except from the pulse inputs in
case of pulse meters)
Remote
Ball / Compact prover
Figure 6-35: Prover flow computer with one local run and remote run
flow computers.
Remote
Master meter pulses
Figure 6-36: Master meter proving based on pulses on a prover flow
computer with remote runs
Remote
Master meter totals
Figure 6-37: Master meter proving based on totalizers on a proving
flow computer with remote runs.
PANEL
RUN X
master
meter
RUN Y
Pu
ls
e
in
Pu
ls
e
in
Pr
ov
e
de
te
ct
or
i
n
D
ig
it
al
ou
t
Pr
ov
e
de
te
ct
or
i
n
PANEL
RUN X
master
meter
RUN Y
(P
ul
se
in
)
(P
ul
se
in
)
Prover pressure(s)
Prover temperature(s)
Prover densitometer
4-way valve commands
Prove start command
Plenum pressure commands
RUN 1
Prover
RUN X
RUN Y
P
ro
ve
d
e
te
ctor
(s
)
in
Pu
ls
e
in
Pu
ls
e
in
Pu
ls
e
in
Pr
ov
er
b
us
p
ul
se
o
ut
Pr
ov
er
b
us
p
ul
se
o
ut
Pr
ov
er
b
us
p
ul
se
in
RUN X
master
meter
RUN Y
RUN Z
Pu
ls
e
in
Pu
ls
e
in
Pr
ov
er
b
us
p
ul
se
o
ut
Pr
ov
er
b
us
p
ul
se
o
ut
Pu
ls
e
in
Pr
ov
er
b
us
p
ul
se
in
Pr
ov
e
de
te
ct
or
i
n
D
ig
it
al
ou
t
RUN X
master
meter
RUN Y
RUN Z
(P
ul
se
in
)
(P
ul
se
in
)
(P
ul
se
in
)