Ordering Information

Product photo

Description

Short
designation

Order code

bbn
40 16779
EAN

Price 
group

Weight
1 pcs
kg

Pack
unit 
Quantity

Optical Smoke Detector

VdS No. G 210145

FC650/O

2CDG 430 079 R0011

86479 4

P6

0.07

1

Static Heat Detector 

VdS No. G 210151

FC650/TMAX

2CDG 430 081 R0011

86477 0

P6

0.07

1

Thermal ROR Detector 

VdS No. G 210151

FC650/TDIFF

2CDG 430 080 R0011

86478 7

P6

0.07

1

Universal Detector Base  
for Series FC650

FC600/BR

2CDG 430 050 R0011

70839 5

P6

0.04

1

Detector Base 12/24 V
for Series FC650

FC600/BREL

2CDG 430 051 R0011

70840 1

P6

0.06

1

Test Aerosol for Smoke  
Detector Testing

FPA03

GH V902 0012 V0021

53444 4

P6

0.3

1

Programming device for reading 
data on the FI700 and FC650 
detector series

FI700/PU

2CDG 430 064 R0011

69824 5

P6

0.2

1

Automatic Fire Detector in Threshold Alarm Technology

Note:

We reserve the right to make technical changes or 
modify the contents of this document without prior 
notice. With regard to purchase orders, the agreed 
particulars shall prevail. 
ABB AG does not accept any responsibility 
whatsoever for potential errors or possible lack of 
information in this document. 

We reserve all rights in this document and in the 
subject matter and illustrations contained 
therein. Any reproduction, disclosure to third parties 
or utilization of its contents - in whole 
or in parts - is forbidden without prior written  
consent of ABB AG. 

Copyright© 2012 ABB 
All rights reserved

ABB STOTZ-KONTAKT GmbH

Eppelheimer Straße 82
69123 Heidelberg, Germany
Phone:  +49 (0)6221 701 607
Fax: 

+49 (0)6221 701 724 

E-Mail: [email protected]

Further Information and Local Contacts: 
www.abb.com/knx 

Data output with FI700/PU

Using the FI700/PU, certain data and values can be read from 
the detector after the respective detector has been screwed 
into the base of the FI700/PU. For this purpose, the corre-
sponding detector series must be selected in the first step on 
the FI700/PU. Then the data can be read. More details can be 
found on the data sheet of the FI700/PU.

Displayed data in dependence on the device type

Function/Device

FC650/O

FC650/TMAX FC650/TDIFF

Type

FC650/O

FC650/T

FC650/T

Quiescent value

x

Pollution in %

x

Type of heat sensor

x

x

Firmware

x

x

x

Manufacturing date

x

x

x

Factory test date

x

x

x

LED function
Battery state in %

x

x

x

Summary of Contents for FC650 Series

Page 1: ...ies offers detectors for different applications The Optical Smoke Detector FC650 O operates according to the scattered light principle and is used where smoke is expected in case of a fire The detector is equipped with a dust barrier that protects the detector both against dust contamination as well as penetration of outside light sources An insect screen prevents intrusion by small insects If fac...

Page 2: ...rm Technology Should there be a requirement to hinder easy removal of the detector from the base a small plastic peg on the side of the detector base can be broken off by inserting a solid object through the aperture on the detector base Only after insertion at the same point for example of a screwdriver is it possible to unlatch the detector and turn it out of the base see Unlatching the detector...

Page 3: ...e base e g using a ferrule or similar device Test activation A test activation can be undertaken by holding a permanent magnet at the smoke inlet aperture level these are also available on the heat detectors located at about 100 in a counter clockwise orientation starting from the rectangular opening on the side of the detector base on the detector Inspection Maintenance Every detector must be phy...

Page 4: ...vail ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document We reserve all rights in this document and in the subject matter and illustrations contained therein Any reproduction disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB AG Copyright 2012 ABB Al...

Reviews: