ACH550-UH User’s Manual
241
Technical Data
Air Flow, 208…240 Volt Drives
The following table lists heat loss and air flow data for 208…240 Volt drives.
Dimensions and Weights
The dimensions and mass for the ACH550 depend on the frame size and enclosure
type. If unsure of frame size, first, find the “Type” code on the drive labels. Then look
up that type code in the
on page 225, to determine the frame size.
A complete set of dimensional drawings for ACH550 drives is located in the ACH550
Technical Reference manual.
-077A-4
R5
1295
4420
168
99
-096A-4
R5
1440
4915
168
99
-124A-4
R6
1940
6621
405
238
-157A-4
R6
2310
7884
405
238
-180A-4
R6
2810
9590
405
238
Drive
Heat Loss
Air Flow
ACH550-UH-
Frame Size
W
BTU/Hr
m
3
/h
ft
3
/min
-04A6-2
R1
55
189
44
26
-06A6-2
R1
73
249
44
26
-07A5-2
R1
81
276
44
26
-012A-2
R1
116
404
44
26
-017A-2
R1
161
551
44
26
-024A-2
R2
227
776
88
52
-031A-2
R2
285
373
88
52
-046A-2
R3
420
1434
134
79
-059A-2
R3
536
1829
134
79
-075A-2
R4
671
2290
280
165
-088A-2
R4
786
2685
280
165
-114A-2
R4
1014
3463
280
165
-143A-2
R6
1268
4431
405
238
-178A-2
R6
1575
5379
405
238
-221A-2
R6
1952
6666
405
238
-248A-2
R6
2189
7474
405
238
Drive
Heat Loss
Air Flow
ACH550-UH-
Frame Size
W
BTU/Hr
m
3
/h
ft
3
/min