213
Signal and parameter list
3ADW000379R0501 DCS550 Manual e e
Signal / Parameter name
m
in.
ma
x.
def
.
uni
t
24.28 TiS2 (2
nd
i-part speed controller)
2
nd
integral time of the speed controller can be released by means of Par2Select (24.29).
Int. Scaling: 1 == 1 ms
Type: I
Volatile:
N
0
64000
2500
ms
24.29 Par2Select (selector for 2
nd
set of speed controller parameters)
Select active speed controller parameters:
0 = ParSet1
parameter set 1 [KpS (24.03) and TiS (24.09)] is active, default
1 = ParSet2
parameter set 2 [KpS2 (24.27) and TiS2 (24.28)] is active
2 = SpeedLevel
If |MotSpeed (1.04)|
≤
|SpeedLev (50.10)|, then parameter set1 is active.
If |MotSpeed (1.04)| > |SpeedLev (50.10)|, then parameter set 2 is active.
3 = SpeedError
If |SpeedErrNeg (2.03)|
≤
|SpeedLev (50.10)|, then parameter set1 is active.
If | SpeedErrNeg (2.03)| > |SpeedLev (50.10)|, then parameter set 2 is active.
4 = DI1
0 = parameter set 1 is active, 1 = parameter set 2 is active
5 = DI2
0 = parameter set 1 is active, 1 = parameter set 2 is active
6 = DI3
0 = parameter set 1 is active, 1 = parameter set 2 is active
7 = DI4
0 = parameter set 1 is active, 1 = parameter set 2 is active
8 = DI5
0 = parameter set 1 is active, 1 = parameter set 2 is active
9 = DI6
0 = parameter set 1 is active, 1 = parameter set 2 is active
10 = DI7
0 = parameter set 1 is active, 1 = parameter set 2 is active
11 = DI8
0 = parameter set 1 is active, 1 = parameter set 2 is active
12 = DI9
0 = parameter set 1 is active, 1 = parameter set 2 is active, only available with digital
extension board
13 = DI10
0 = parameter set 1 is active, 1 = parameter set 2 is active, only available with digital
extension board
14 = DI11
0 = parameter set 1 is active, 1 = parameter set 2 is active, only available with digital
extension board
15 = MCW Bit11
0 = parameter set 1 is active, 1 = parameter set 2 is active, MainCtrlWord (7.01) bit 11
16 = MCW Bit12
0 = parameter set 1 is active, 1 = parameter set 2 is active, MainCtrlWord (7.01) bit 12
17 = MCW Bit13
0 = parameter set 1 is active, 1 = parameter set 2 is active, MainCtrlWord (7.01) bit 13
18 = MCW Bit14
0 = parameter set 1 is active, 1 = parameter set 2 is active, MainCtrlWord (7.01) bit 14
19 = MCW Bit15
0 = parameter set 1 is active, 1 = parameter set 2 is active, MainCtrlWord (7.01) bit 15
Note:
Load and speed dependent adaptation parameters are valid regardless of the selected parameter set.
Int. Scaling: 1 == 1
Type: C
Volatile:
N
Pa
rSe
t1
M
C
W
B
it
15
Pa
rSe
t1
Group 25: Torque reference
25.01 TorqRefA (torque reference A)
External torque reference in percent of MotNomTorque (4.23). TorqRefA (25.01) can be scaled by LoadShare
(25.03).
Note:
TorqRefA (25.01) is only valid, if TorqRefA Sel (25.10) = TorqRefA2501.
Int. Scaling: 100 == 1 % Type: SI
Volatile:
Y
-325
325
0
%
25.02 Unused
25.03 LoadShare (load share)
Scaling factor TorqRefA (25.01).
Int. Scaling: 10 == 1 %
Type: SI
Volatile:
N
-400
400
100
%
25.04 - 24.09 Unused
25.10 TorqRefA Sel (torque reference A selector)
Selector for TorqRefExt (2.24):
0 = TorqRefA2501 TorqRefA (25.01), default
1 = AI1
analog input AI1
2 = AI2
analog input AI2
3 = AI3
analog input AI3
4 = AI4
analog input AI4
5 = AI5
analog input AI5
6 = AI6
analog input AI6
Int. Scaling: 1 == 1
Type: C
Volatile:
N
T
or
qR
ef
A
2
501
AI
6
T
or
qR
ef
A
2
501
-
Summary of Contents for DCS550 Series
Page 1: ... DCS550 Manual DCS550 Drives 20 A to 1000 A ...
Page 141: ...141 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 143: ...143 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 145: ...145 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 147: ...147 Winder 3ADW000379R0501 DCS550 Manual e e ...