Signal and parameter list
3ADW000379R0501 DCS550 Manual e e
Signal / Parameter name
m
in.
ma
x.
def
.
uni
t
14.16 DO8BitNo (digital output 8 bit number)
Bit number of the signal/parameter selected with DO8Index (14.15).
Int. Scaling: 1 == 1
Type: I
Volatile:
N
0
15
7
-
Group 15: Analog outputs
15.01 IndexAO1 (analog output 1 index)
Analog output 1 is controlled by a source (signal/parameter) selected with IndexAO1 (15.01). The format is -
xxyy, with: - = negate analog output, xx = group and yy = index.
Int. Scaling: 1 == 1 Type: SI
Volatile:
N
-9999
9999
0
-
15.02 CtrlWordAO1 (control word analog output 1)
Analog output 1 can be written to via CtrlWordAO1 (15.02) using AP or overriding control if IndexAO1 (15.01)
is set to zero. Further description see group 19 Data Storage.
Int. Scaling: 1 == 1 Type: SI
Volatile:
Y
-
3276
8
32767
0
-
15.03 ConvModeAO1 (convert mode analog output 1)
Analog output 1 signal offset:
0 =
±
10V Bi
-10 V to 10 V bipolar output, default
1 = 0V-10V Uni
0 V to 10 V unipolar output
2 = 2V-10V Uni
2 V to 10 V unipolar output
3 = 5V Offset
5 V offset in the range 0 V to 10 V for testing or indication of bipolar signals (e.g. torque,
speed, etc.)
4 = 6V Offset
6 V offset in the range 2 V to 10 V for testing or indication of bipolar signals (e.g. torque,
speed, etc.)
5 = 0V-10V Abs
absolute 0 V to 10 V unipolar output (negative values are shown positive)
Int. Scaling: 1 == 1
Type: C
Volatile:
N
±
1
0
V Bi
0V
-1
0
V Ab
s
±
1
0
V Bi
-
15.04 FilterAO1 (filter analog output 1)
Analog output 1 filter time.
Int. Scaling: 1 == 1 ms
Type: I
Volatile:
N
0
10000
0
ms
15.05 ScaleAO1 (scaling analog output 1)
100 % of the signal/parameter selected with IndexAO1 (15.01) is scaled to the voltage in ScaleAO1 (15.05).
Example:
In case the min. / max. voltage (
±
10 V) of analog output 1 should equal
±
250 % of TorqRefUsed (2.13), set:
−
IndexAO1 (15.01) = 213,
−
ConvModeAO1 (15.03) =
±
10V Bi and
−
ScaleAO1 (15.05) = 4000 mV
Int. Scaling: 1 == 1 mV
Type: I
Volatile:
N
0
10000
10000
mV
15.06 IndexAO2 (analog output 2 index)
Analog output 2 is controlled by a source (signal/parameter) selected with IndexAO2 (15.06). The format is -
xxyy, with: - = negate analog output, xx = group and yy = index.
Int. Scaling: 1 == 1
Type: SI
Volatile:
N
-9999
9999
0
-
15.07 CtrlWordAO2 (control word analog output 2)
Analog output 2 can be written to via CtrlWordAO2 (15.07) using AP or overriding control if IndexAO2 (15.06)
is set to zero. Further description see group 19 Data Storage.
Int. Scaling: 1 == 1 Type: SI
Volatile:
Y
-
3276
8
32767
0
-
15.08 ConvModeAO2 (convert mode analog output 2)
Analog output 2 signal offset:
0 =
±
10V Bi
-10 V to 10 V bipolar output, default
1 = 0V-10V Uni
0 V to 10 V unipolar output
2 = 2V-10V Uni
2 V to 10 V unipolar output
3 = 5V Offset
5 V offset in the range 0 V to 10 V for testing or indication of bipolar signals (e.g. torque,
speed, etc.)
4 = 6V Offset
6 V offset in the range 2 V to 10 V for testing or indication of bipolar signals (e.g. torque,
speed, etc.)
5 = 0V-10V Abs
absolute 0 V to 10 V unipolar output (negative values are shown positive)
Int. Scaling: 1 == 1
Type: C
Volatile:
N
±
1
0
V Bi
0V
-1
0
V Ab
s
±
1
0
V Bi
-
Summary of Contents for DCS550 Series
Page 1: ... DCS550 Manual DCS550 Drives 20 A to 1000 A ...
Page 141: ...141 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 143: ...143 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 145: ...145 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 147: ...147 Winder 3ADW000379R0501 DCS550 Manual e e ...