CPS6000 Power System

 

• 

Wire cutters and strippers

 

• 

Digital meter, +/

-

 0.02%

 

• 

5/16”

and 

3/8” 

nut drivers and sockets

 

• 

Heat shrink gun

 

• 

Screw Drivers (#1 and #2 Phillips)

 

 

• 

Torque wrench (0

-

240 in

-

lb / 28 Nm)

 

• 

Cable crimpers

 

 

Information – Tools Required

 

For systems with rear access AC terminal box.

 

The shelf is installed with a minimum gap of 3/4 inch below the system to allow proper airflow. Attach the CPS 
shelf to the frame using a minimum of twelve (six on each side) of the 12

-

24 screws included with the shelf.

 

QUICK START GUIDE

 

Summary of Contents for CPS6000

Page 1: ...sockets Heat shrink gun Screw Drivers 1 and 2 Phillips Torque wrench 0 240 in lb 28 Nm Cable crimpers Information Tools Required For systems with rear access AC terminal box The shelf is installed wit...

Page 2: ...AC Input cords Each Rectifier shelf comes equipped with rear access terminal blocks and conduit fittings for ac connection The AC feeds may be either 110 VAC or 208 220VAC depending on the rectifier t...

Page 3: ...able DC Connections are made with double hole lugs on 20 studs on 5 8 centers The maximum tongue width for breaker connections is 0 68 Load and battery cabling showing multi pole adapters installed in...

Page 4: ...Connect LAN Office Alarm Alarm Inputs and Thermal Probes to J5 J4 J3 and J2 respectively as shown right Special Cables are available for these purposes if required Step 6 Initial Start Up Verify that...

Page 5: ...o reflect the system alarm status as follows Green Normal Amber Minor Alarms Present Red Major Alarms Active The up and down arrow keys can be used to adjust screen contrast when the controller is dis...

Page 6: ...ctor J4 provides access to the primary customer alarm output interface Connector J4 is a 20 pin right angle header with latching capability Standard color coded cable assemblies are available Office A...

Page 7: ...ts reserved CPS6000_Series II External Distribution_QSG Version 2 0 Version Date Description of the change 1 0 07 2012 Initial release 2 0 07 11 2023 Updated as per ABB template Change History exclude...

Page 8: ...ail ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document We reserve all rights in this document and in the subject matter and illustr...