7.4 Bench and Function Tests
Set dip switches
SW3
and
SW4 = OFF
to be able to run the bench and function
tests for the CP410. Turn on the operator terminal to display the following
screen:
The following items are tested:
7.5 Setting Parameters
There are two ways to configure working parameters; to set parameters in the
operator terminal or in CP400Soft.
To set parameters in the operator terminal, select
F7 - Confg
in the system
menu.
To set parameters in CP400Soft, select
Application/Workstation Setup
. Select
the
Connection
tab to set communication parameters.
CP410
Description
F9 - Bench test
Keyboard Test: 16 keys
BIOS: System RAM, Flash memory, Buzzer, LED, BIOS, Battery
Status, RTC, COM port, Flash ROM
F6 - Function Test
F1: LED
F2: Buzzer
F3: DIP SW
F4: LCD
F5: RS232
F6: RS422
F7: RS485
F8: KEY
Note:
Remember to set dip switch
SW5 = ON
if parameters are set in the operator ter-
minal.
Note:
Remember to set dip switch
SW5 = OFF
if parameters are set in CP400Soft.