background image

ControlMaster CM10, CM15, CM30, CM50, CMF160 and CMF310

Universal process controllers and indicator, 

1

/

8

1

/

4

1

/

2

 DIN and fieldmount

3 Communication Overview

6

IM/CM/C–EN Rev. H

3 Communication Overview

Extensive communication options enable the ControlMaster to be integrated into larger control systems easily or connected to
other process instrumentation.

3.1 Communication Options

3.1.1 Ethernet

Optional Ethernet communications enable the ControlMaster to be integrated in to an Ethernet network quickly. 

The following functionality is provided:

Email

Notification of a critical process event or status can be made by email. Multiple events can trigger an email that can be
sent to multiple recipients.

Webserver

ControlMaster's integrated webserver enables the current status of the process and controller to be viewed remotely
using a standard web browser.

MODBUS TCP

Process values and status can be communicated to and from the ControlMaster in real-time using MODBUS TCP,
enabling it to be integrated easily into larger control systems or connected to a data recorder.

Summary of Contents for ControlMaster CM10

Page 1: ...easurement made easy ABB ME ASUREMENT ANALY TICS COMMUNIC ATIONS SUPPLEMENT IM CM C EN REV H ControlMaster CM10 CM30 CM50 CMF160 and CMF310 Universal process controllers 1 8 1 4 1 2 DIN and fieldmount...

Page 2: ...eldmount DS CMF310 EN Data Sheet ControlMaster CMF160 Universal process indicator fieldmount DS CMF160 EN Search for or click on Data Sheet ControlMaster CM15 Universal process indicator 1 8 DIN DS CM...

Page 3: ...5 3 Two wire and Four wire Connection 16 5 4 Pull up and Pull down Resistors 17 5 5 Termination Resistor 17 5 6 Serial Connections 18 6 MODBUS Tables 19 6 1 Input Coils Digital Inputs MODBUS Function...

Page 4: ...ts 2 IM CM C EN Rev H 6 6 Holding Registers MODBUS Function Code 03 Read Holding Register or 06 Write Holding Register 24 6 6 1 Writable 16 Bits 24 6 6 2 Writable 32 Bits 24 6 6 3 Writable Single Prec...

Page 5: ...ent complies with the requirements of CEI IEC 61010 1 2001 2 Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use and complies with US NEC 500 NIST and OSHA If the e...

Page 6: ...ng Warning labels on containers and packages must be observed Installation operation maintenance and servicing must be carried out only by suitably trained personnel and in accordance with the informa...

Page 7: ...ctions and configuration tables and Ethernet connection details 2 1 EC Directive 89 336 EEC In order to meet the requirements of the EC Directive 89 336 EEC for EMC regulations this product must not b...

Page 8: ...the ControlMaster to be integrated in to an Ethernet network quickly The following functionality is provided Email Notification of a critical process event or status can be made by email Multiple even...

Page 9: ...icator 1 8 1 4 1 2 DIN and fieldmount 3 Communication Overview IM CM C EN Rev H 7 3 1 2 RS 485 MODBUS Using RS 485 MODBUS values and status can be communicated to and from the controller in real time...

Page 10: ...tted MODBUS parameters are enabled but Ethernet parameters are not enabled or displayed Used to setup communications parameters for the MODBUS Ethernet email communication protocols MODBUS Refer to Se...

Page 11: ...e MODBUS serial communication serial link as 2 Wire 4 Wire or Off see Section 5 3 page 16 Baud Rate A selectable communication transfer rate up to 115 2 K baud bits per second maximum default 19200 ba...

Page 12: ...MODBUS TCP network fixed at 502 Connections Select the maximum number of simultaneous TCP IP connections permitted minimum 1 maximum 3 Client Authority Select the number of authorized TCP IP connecti...

Page 13: ...col to distinguish between different devices The address is a 32 bit value expressed with 4 values 0 to 255 each separated by a period Note Configurable only if DHCP is disabled Subnet Mask The subnet...

Page 14: ...port Protocol server used to distribute emails Recipients Email Address 1 3 Enter the email address es of the recipient s Triggers Tag 1 4 The trigger description that appears in the subject title Sou...

Page 15: ...422 485 communications driver must fitted to the host master computer It is strongly recommended that the interface has galvanic isolation to protect the computer from lightning damage and to increase...

Page 16: ...It is strongly recommended that screened cable is used for signal inputs and relay connections ControlMaster CM10 CM30 and CM50 controllers and CM15 indicator conform to Mains Power Input Overvoltage...

Page 17: ...ctions Overview COMMUNICATIONS MODULE SK1 SK2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 13 14 15 16 17 18 1 2 3 4 5 6 7 8 9 10 11 12 19 20 21 22 23 1 2 3 4 5 Tx Tx Rx Rx Common Tx Rx Tx Rx Common T...

Page 18: ...ee Fig 5 2 The instrument must be added to the link configuration on the host system refer to information supplied with the host system Fig 5 2 2 Wire and 4 Wire MODBUS Serial Links MODBUS Comms MODBU...

Page 19: ...S422 485 interface in the host computer Resistors are normally connected to the interface by hard wired links or switches refer to the manufacturer s instructions 5 5 Termination Resistor For long tra...

Page 20: ...e slaves must be made in parallel as shown in Fig 5 3 When connecting cable screens ensure that ground loops are not introduced The maximum serial data transmission line length for both RS422 and RS48...

Page 21: ...log Input 2 digital Value 7 Analog Input 3 digital Value 8 Analog Input 4 digital Value 9 Math Block 1 Fail 10 Math Block 2 Fail 11 Math Block 3 Fail 12 Math Block 4 Fail 13 Math Block 5 Fail 14 Math...

Page 22: ...2 State 51 Alarm 1 State 52 Alarm 1 Ack State 53 Alarm 2 State 54 Alarm 2 Ack State 55 Alarm 3 State MODBUS Coil Title 56 Alarm 3 Ack State 57 Alarm 4 State 58 Alarm 4 Ack State 59 Alarm 5 State 60 Al...

Page 23: ...ingle Coil MODBUS Coil Title 144 Program Event 1 145 Program Event 2 146 Program Event 3 147 Program Event 4 148 Program Event 5 149 Program Event 6 150 Program Event 7 151 Program Event 8 152 PV Even...

Page 24: ...1 Man 2 Loop 2 Auto Manual State 0 Auto 1 Man 3 Loop 1 Setpoint Mode 0 Local 1 Remote 4 Loop 2 Setpoint Mode 0 Local 1 Remote 5 Totalizer 1 Run State 6 Totalizer 2 Run State 7 Loop 1 Tracking State 8...

Page 25: ...2 5061 Loop 2 Split Output 1 5063 Loop 2 Split Output 2 5065 Process Variable 1 Max 5067 Process Variable 2 Max 5069 Process Variable 1 Min 5071 Process Variable 2 Min 5073 Process Variable 1 Ave 5075...

Page 26: ...er Title 0001 Output 1 0002 Output 2 0003 Instrument Type 0004 Instrument I O build 0005 Instrument Functionality MODBUS Register Title 2001 Alarm 1 Time Hysteresis 2002 Alarm 2 Time Hysteresis 2003 A...

Page 27: ...Setpoint 1 6641 Loop 1 Local Setpoint 2 6643 Loop 1 Local Setpoint 3 6645 Loop 1 Local Setpoint 4 6647 Loop 1 Remote Setpoint Ratio 6649 Loop 1 Remote Setpoint Bias 6661 Loop 2 Local Setpoint 1 6663...

Page 28: ...Time 3 6797 Loop 1 Manual Reset 6803 Loop 1 Feedforward Gain 6817 Loop 2 Proportional Band 1 6819 Loop 2 Integral Time 1 6821 Loop 2 Derivative Time 1 6823 Loop 2 Proportional Band 2 6825 Loop 2 Inte...

Page 29: ...llers and indicator 1 8 1 4 1 2 DIN and fieldmount 6 MODBUS Tables IM CM C EN Rev H 27 6 6 4 Profile MODBUS Register Title 851 Profile Run 852 Program Number 853 Loop 1 Auto Manual 854 Loop 2 Auto Man...

Page 30: ...nt 7 Ethernet Connections 28 IM CM C EN Rev H 7 Ethernet Connections 7 1 CM10 CM15 CM30 and CM50 Standard Connections Rear View Rear View CM10 CM15 CM30 CM50 Remove existing terminal screws and screw...

Page 31: ...te Isolate the instrument from the power supply before removing the terminal cover Fit cable gland to ethernet cable to maintain IP rating as required Connect ethernet cable plug to socket on ethernet...

Page 32: ...fitted per controller Type 10Base T Connector RJ45 Protocols TCP IP HTTP MODBUS TCP slave Web server Built in enables remote monitoring using standard web browsers Email Can be configured to be sent...

Page 33: ...Sales Service Software...

Page 34: ...ght to make technical changes or modify the contents of this document without prior notice With regard to purchase orders the agreed particulars shall prevail ABB does not accept any responsibility wh...

Reviews: