Note: Configuration must be completed before adjusting Setup parameters. 

First select Setup mode from Select mode (refer to section 2). While in Setup Mode     is lit. 

Press        to scroll through the parameters, then press  

  or         to set the required value.  

To exit from Setup mode, hold down        and press       , to return to Select mode. 

Note: Parameters displayed depends on how instrument has been configured. 

Parameter 

Lower 

Display 

Upper Display 

Adjustment Range 

Default 

Input Filter Time constant 









OFF or 0.5 to 100.0 secs 

.



Process Variable Offset 









+/- Span of controller 



Primary (Heat) power 

PPWw

PPWw

PPWw

PPWw 

 

 

 

Secondary (Cool) power 

SPWw

SPWw

SPWw

SPWw 

 

 

 

Current power levels (read only) 

N/A 

Primary Proportional Band 









Secondary Proportional Band 









0.0% (ON/OFF) and 0.5% to 

999.9% of input span. 









.



Automatic Reset (Integral Time) 









1 sec to 99 mins 59 secs and OFF 

.









Rate (Derivative Time) 









00 secs to 99 mins 59 secs 

.





Overlap/Deadband 









-20 to +20% of Primary and 

Secondary Proportional Band



Manual Reset (Bias)  









0%(-100% if dual control) to 100% 









Primary ON/OFF Differential 









Secondary ON/OFF Diff. 









Prim. & Sec. ON/OFF Diff. 









0.1% to 10.0% of input span 

centered about the setpoint 

.



Setpoint Upper Limit 









Current Setpoint to Range max 

R/max 

Setpoint Lower limit 









Range min to Current Setpoint 

R/min 

Primary Output Power Limit 









0% to 100% of full power. 









Output 1 Cycle Time 









Output 2 Cycle Time 









0.5, 1, 2, 4, 8, 16, 32, 64, 128, 

256 or 512 seconds 









High Alarm 1 value 









R/max 

Low Alarm 1 value 









Range Min. to Range Max. 

R/min 

Deviation Alarm 1 Value 









+/- Span from SP in display units 



Band Alarm 1 value 









1 LSD to span from setpoint 



Alarm 1 Hysteresis 









1 LSD to full span in display units 



High Alarm 2 value 









R/max 

Low Alarm 2 value 









Range Min. to Range Max. 

R/min 

Deviation Alarm 2 Value 









+/- Span from SP in display units 



Band Alarm 2 value 









1 LSD to span from setpoint 



Alarm 2 Hysteresis 









1 LSD to full span in display units 



Loop Alarm Time 









1 sec to 99 mins. 59secs. 









.









Auto Pre-tune 









Auto/manual Control selection 









Setpoint ramping 

















disabled or  









   

enabled

 









SP Ramp Rate Value 

rP

rP

rP

rP 

 

 

 

1 to 9999 units/hour or Off (blank) 

Off 

Setpoint Value 

SP

SP

SP

SP 

 

 

 

Scale range upper to lower limits 

Scale 

Range 

min 

Setup Lock Code 









0 to 9999 









 

First select Automatic tuning mode from Select mode (refer to section 2). 

Press        to scroll through the modes, then press  

  or  

  to set the required value.  

To exit from Automatic tuning mode, hold down        and press     , to return to Select mode.  

Pre-tune is a single-shot routine and is thus self-disengaging when complete. 
If 









  in Setup mode = 









, Pre-tune will attempt to run at every power up*. 

Parameter 

Lower 

Display 

Upper Display 

Adjustment Range 

Default 

Pre-Tune 









Self-Tune 















On

On

On

On

 or 

Off

Off

Off

Off. 

Indication remains 

OFF

OFF

OFF

OFF

 if automatic 

tuning cannot be used at this time*. 

Off

Off

Off

Off

Tune Lock 









0 to 9999 



* Note: Automatic tuning will not engage if either proportional band = 0. Also, Pre-tune

will not engage if setpoint is ramping, or the PV is within 5% of span of the setpoint. 

 

First select Product information mode from Select mode (refer to section 2). 

Press       to view each parameter. To exit from Product Information mode, hold down  

and press  

  to return to Select mode. Note: These parameters are all read only. 

Parameter 

Lower 

Display 

Upper 

Display 

Description 

Input type 

















Universal input only 









No option fitted. 

Option 1 module type 

fitted 

















Relay 









No option fitted. 

Option 2 module type 

fitted 

















Relay 

Option 3 

















Option 3 not available on this 

product 

Option A 

















Option A not available on this 

product 

Firmware type 









Value displayed is firmware type number 

Firmware issue 









Value displayed is firmware issue number 

Product Revision Level 









Value displayed is Product Revision level.  

Date of manufacture 









Mm

Mm

Mm

Mm

Manufacturing date code (mmyy) 

Serial number 1 









First four digits of serial number 

Serial number 2 









Middle four digits of serial number 

Serial number 3 









Last four digits of serial number 

 
This mode is entered at power on. It can also be accessed from Select mode (see section 2). 

Note: All configuration mode and Setup mode parameters must be set as required 

before starting normal operations. 

Press        to scroll through the parameters, then press         or         to set the required value. 

Note: All parameters in Display strategy 6 are read only, and can only be adjusted via 

Setup mode.  

Upper 

Display 

Lower 

Display 

Display Strategy 

When Visible 

Description 

PV Value 

Active SP 

Value 

1 & 2 (initial screen) 

PV and target value of selected SP 

SP adjustable in Strategy 2 

PV Value 

Actual SP 

Value 

3 & 6 (initial screen) 

PV and actual value of selected SP 

(e.g. ramping SP value). Read only 

PV Value 

(Blank) 

4 (initial screen) 

Process variable only. Read only 

Active SP 

Value 

(Blank) 

5 (initial screen) 

Target value of selected setpoint only. 

Read only 

SP Value 

SP

SP

SP

SP 

 

 

 

1, 3, 4, 5 & 6 

Target value of SP 

Adjustable except in Strategy 6 

Actual SP 

Value 

SPrP

SPrP

SPrP

SPrP 

 

 

 









 enabled and 

rP

rP

rP

rP

 

is not zero 

Actual (ramping) value of selected SP 

Read only 

Ramp 

Rate  

rP

rP

rP

rP 

 

 

 









 enabled in Setup 

mode 

SP ramping rate, in units per hour. 

Adjustable except in Strategy 6 

Active 

Alarms 

AL

AL

AL

AL

t

t

t

 

 

 

When one or more 

alarms are active. 

ALM indicator 

will also flash

 

L

 

 

  Alarm 2 active 

L21

L21

L21

L21

     Alarm 1 active 

L

  

  Loop Alarm active

 

 

 

 

Manual Control 
If 









 is set to 









 in Setup mode, manual control can be selected/de-selected by 

pressing the        key while in Operator mode. The        indicator will flash while in the 
instrument is in Manual Control mode and the lower display will show 

xxx (where xxx is the 

current manual power level). Switching to/from manual mode is via Bumpless Transfer. 
Press  

  or  

  to set the required output power. Caution: Not restricted by 









 limit. 

Parameter 

Upper 

Display 

Lower 

Display 

Description 

Instrument 

parameters are in 

default conditions 

















 

Configuration & Setup required. Seen at first 

turn on or if hardware configuration changed. 

Press        to enter the Configuration Mode, 

next press         or     to enter the unlock 

code number, then press  

  to proceed. 

Over Range 











Normal 

Input > 5% over-range 

Under Range 











Normal 

Input > 5% under-range 

Sensor Break 









Normal 

Break in input sensor or wiring 

Option 1 Error 









Option 1 module fault 

Option 2 Error 

















Option 2 module fault 

UNIVERSAL INPUT 

Impedance: 

>10M

 resistive, except DC mA (5

) and V (47k

 ).

Isolation: 

Isolated from relay outputs and power supply at 240VAC.

OUTPUTS 

Relay 

Contact Type/Rating:  Single pole double throw (SPDT); 2A resistive at 120/240VAC. 

Lifetime: 

>500,000 operations at rated voltage/current. 

Isolation: 

Isolated from input, other relay outputs and power supply at 240VAC. 

OPERATING CONDITIONS FOR INDOOR USE 

Ambient Temperature:  0°C to 55°C (Operating) 

Ambient Temperature:  –20°C to 80°C  (Storage) 

Relative Humidity: 

20% - 95% non-condensing 

Supply Voltage: 

100 - 240VAC 50/60Hz 7.5VA for mains powered versions. 

ENVIRONMENTAL 

Standards: 

CE, UL, ULC 

EMI: 

Complies with EN61326 (Susceptibility & Emissions) 

Safety Considerations:  Complies with EN61010-1 & UL3121 

Pollution Degree 2, Installation Category II 

Front Panel Sealing:  To IP66 

PHYSICAL 

Dimensions Depth: 

110mm (behind panel) 

Front panel height: 

48mm 

Front panel width: 

48mm 

Weight: 

0.21kg maximum 

4. SETUP MODE

6. PRODUCT INFORMATION MODE

7. OPERATOR MODE

8. ERROR/FAULT INDICATIONS 

 

8

.

 

SPECIFICATIONS

5. AUTOMATIC TUNING MODE

Reviews: