![ABB Busch-Watchdog 6747-500 AGM Series Operating Instructions Manual Download Page 18](http://html1.mh-extra.com/html/abb/busch-watchdog-6747-500-agm-series/busch-watchdog-6747-500-agm-series_operating-instructions-manual_3431397018.webp)
Operating Instructions
Busch-Wächter
®
Operation
Operating Instructions | 1473-1-8136
— 18 —
8.4.2
Deleting programmed devices
Tor delete all programming take the following steps:
Fig. 19: Selector switch of the receiver
1. Set the selector switch of receiver 6701 on "E", LED flashes red.
Fig. 20: Programming button
2. Press the programming button on receiver 6701 (2), the LED (1) lights permanently red.
Fig. 21: Set the selector switch on “P”.
3. Set the selector switch of the Busch-Watchdog on "P", the status LED lights up for approx. 10 seconds (with a
slight delay).
4. The link will be deleted.
5. After a successful deleting process, the LED starts to flash red again. If the deleting procedure is not
successful (the LED continues to light up), reset the selector switch on the Busch-Watchdog to “E”again and
repeat the procedure.
6. Set the operating mode of
receiver 6701
on "R" or "S" or program additional Watchdogs.
7. Select the operating mode of the
Busch-Watchdog
on “ES” or “GS”.
Pos: 43 /#Neustruktur#/Online-Dokumentation (+KNX)/Steuermodule - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenu+++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1
P
R
S
E
A
E
1+2
T
B
GS
ES
P