![ABB Aztec AWT440 Commissioning Instructions Download Page 17](http://html.mh-extra.com/html/abb/aztec-awt440/aztec-awt440_commissioning-instructions_4350017.webp)
CI/AWT440–EN Rev. A
17
Display icons
Alarm, hold, clean and calibration icons
Title bar icons
Status bar icons
Alarm – indicates a user-defined alarm condition
(20-character) and flashes intermittently with an
associated NAMUR diagnostic icon.
Hold – indicates that alarms / analog outputs are in
a manual hold state.
Calibrating – indicates that a calibration is in
progress.
Cleaning – indicates that a manual or automatic
clean is in progress.
Log mode – indicates that one of the
View
pages is
currently displayed (
Calibration, Alarm, Audit or
Diagnostic
).
View mode – indicates that one of the
View
pages is
currently displayed (
Diagnostics, Alarms, Outputs,
Signals
or
Chart
).
Media on-line: 0 to <20 % full.
Media on-line: 20 to <40 % full.
Media on-line: 40 to <60 % full.
Media on-line: 60 to <80 % full.
Media on-line: 80 to <100 % full.
Media on-line: full (icon toggles when full).
Media off-line: 0 to <20 % full.
Media off-line: 20 to <40 % full.
Media off-line: 40 to <60 % full.
Media off-line: 60 to <80 % full.
Media off-line: 80 to <100 % full.
Media off-line: not inserted (not logging).
Media off-line: not inserted, logging active
– icon display toggles with
Media off-line: not
inserted (not logging) icon
.
Operator menu – displays the Operator menu when
the
key is pressed.
Autoscroll – indicates that
Operator
pages are
displayed sequentially. Displayed only when
Autoscroll
enabled from the Operator menu.
Disabled if 1
Operator
page only is configured for
display.
Calibration – shortcut access to the Calibration
page when the
key is pressed.
Enter – selects the highlighted option from the
Operator menus when the
key is pressed.
Service Level – indicates that alarms and analog
outputs are held.
Advanced Level – indicates that
Advanced Level
parameters are enabled for the current user.
Calibrate Level – indicates that the
Calibration Level
parameters are enabled for the current user.
Read Only Level – indicates that the transmitter is in
Read Only mode.
All parameters are locked and
cannot be configured.
Cleaning – indicates that a manual or automatic
clean is in progress.
In Hold Mode – indicates that alarms / analog
outputs are in a manual hold state.
High process alarm active / inactive.
Low process alarm – active / inactive.
High latch alarm – active / inactive.
Low latch alarm – active / inactive.