background image

 

ATS-16 A 

 
 

STATUS 

Approved 

SECURITY LEVEL 

Public 

DOCUMENT ID. 

4NWD003885 

REV. 

LANG. 

EN 

PAGE 

3/18 

© Copyright 2019 ABB. All rights reserved. 

 

Contents 

1. Important safety instructions ...................................................................................................................... 4

 

1.1. Save these instructions ....................................................................................................................................... 4

 

1.2. Safety rules ............................................................................................................................................................ 4

 

2. Installation .......................................................................................................................................................6

 

2.1. Receipt and visual inspection ............................................................................................................................ 6

 

2.2. Unpacking list ....................................................................................................................................................... 6

 

2.3. Storage ................................................................................................................................................................... 6

 

2.4. Handling ................................................................................................................................................................. 6

 

2.5. Environmental conditions ................................................................................................................................... 7

 

2.6. Rack Mounting ...................................................................................................................................................... 8

 

2.7. Dimensions of area .............................................................................................................................................. 8

 

3. Installation ....................................................................................................................................................... 9

 

3.1. Configuration of the ATS-16 A system ............................................................................................................. 9

 

3.2. Technical Data ....................................................................................................................................................... 9

 

3.2.1. Block Diagram ........................................................................................................................................ 9

 

3.2.2. ATS-16 A Technical Data ...................................................................................................................... 10

 

3.3. External Protection and Isolation Devices .................................................................................................... 13

 

3.4. Front panel ........................................................................................................................................................... 14

 

3.5. Rear Panel ............................................................................................................................................................. 14

 

3.6. Operating Panel................................................................................................................................................... 14

 

3.7. Description of the system ................................................................................................................................. 16

 

4. Manual Switch ON Procedures ..................................................................................................................... 17

 

4.1. First Switch on from Source A .......................................................................................................................... 17

 

4.2. First Switch on from Source B ......................................................................................................................... 17

 

4.3. Switch OFF ........................................................................................................................................................... 17

 

5. Troubleshooting ............................................................................................................................................ 18

 

5.1. Fault identification and rectification .............................................................................................................. 18

 

 
 

 

Summary of Contents for ATS-16 A

Page 1: ...APPROVED 2019 05 22 Gabriele Poccia DOCUMENT KIND Operating manual OWNING ORGANIZATION ABB Electrification Smart Power business line DOCUMENT ID 4NWD003885 REV A LANG EN PAGE 1 18 Copyright 2019 ABB All rights reserved OPERATING MANUAL ATS 16 A Automatic Transfer Switch 230 VAC ...

Page 2: ...symbol in conjunction with the signal word WARNING indicates a potentially dan gerous situation Failure to observe may cause injury death or equipment damage This symbol indicates a safety note ATTENTION Hazardous voltage Installation by a certified service engineer only This symbol in conjunction with the signal word NOTE indicates operator tips or partic ularly useful or important information fo...

Page 3: ...ronmental conditions 7 2 6 Rack Mounting 8 2 7 Dimensions of area 8 3 Installation 9 3 1 Configuration of the ATS 16 A system 9 3 2 Technical Data 9 3 2 1 Block Diagram 9 3 2 2 ATS 16 A Technical Data 10 3 3 External Protection and Isolation Devices 13 3 4 Front panel 14 3 5 Rear Panel 14 3 6 Operating Panel 14 3 7 Description of the system 16 4 Manual Switch ON Procedures 17 4 1 First Switch on f...

Page 4: ...ended for people who plan the installation and use of the product The reader is expected to know the fundamentals of electricity wiring electrical compo nents and electrical schematic symbols READ ALL SAFETY AND OPERATING INSTRUCTIONS BEFORE OPERATING THE ATS 16A AUTOMATIC TRANSFER SWITCH SYSTEM OBSERVE TO ALL WARNINGS ON THE UNIT AND IN THIS MANUAL BY NOT FULFILLING THIS OBLIGATION THE PRODUCT MA...

Page 5: ...UTOMATIC TRANSFER SWITCH system must observe the in structions in this manual Any deviations from the instructions could be dangerous to the user or cause accidental load loss THE MANUFACTURER WILL NOT BE HELD RESPONSIBLE FOR DAMAGES CAUSED THROUGH INCORRECT MANIPULATION OF THE UPS SYSTEM DANGER IT IS PROHIBITED TO REMOVE ANY PARTS FROM THE ATS 16A AUTOMATIC TRANSFER SWITCH SYSTEM OR FROM ANY OPTI...

Page 6: ...THE SUPPLIER AS SOON AS POSSIBLE 2 2 Unpacking list The ATS 16 A is available voltage level 220 230 240VAC Nominal current 16 A ATS 16 A module 2 pluggable input power cables p n 108 00140 xx Bracket kits for rack mounting and vertical mounting NOTE 1 An approved power cord greater or equal to H05VV F 3G 0 75mm2 must be used 2 3 Storage Storage temperature 25 70 C Storage humidity 10 90 2 4 Handli...

Page 7: ...ts reserved 2 5 Environmental conditions NOTE THE ATS 16 A MUST BE EITHER RACK MOUNTED OR INSTALLED ON A LEVEL AND EVEN SURFACE IN AN AREA PROTECTED FROM EXTREMES OF TEMPERATURE WATER AND HUMIDITY AND FROM THE PRESENCE OF CONDUCTIVE POWDER OR DUST WARNING DO NOT STACK UNITS AND DO NOT PLACE ANY OBJECTS ON TOP OF THE UNIT ...

Page 8: ...le of supporting the unit with the corresponding rails or brackets The ATS 16 A scope of supply contains two brackets for fixing the ATS 16 A into a 19 inch rack or into a cabinet with 19 inch inner design Vertical mounting is also possible with the ATS 16 A 2 7 Dimensions of area NOTE IT IS NECESSARY TO LEAVE A MINIMUM SPACE OF A FEW CENTIMETERS ON THE RIGHT LEFT AND REAR TO ALLOW THE FLOW OF AIR...

Page 9: ...Installation 3 1 Configuration of the ATS 16 A system The ATS 16 A provides high reliability supply by switching the load to one of two possible power supplies Primarily these two supplies are UPS devices with sinusoidal output only These UPS devices must operate on the double conversion principle 3 2 Technical Data 3 2 1 Block Diagram ...

Page 10: ...age low loss volts 10 V Input voltage high comeback Input voltage high loss volts 10 V Nominal current 16 A Nominal frequency 50 60 Hz selectable Input frequency range Nominal frequency 15 Output features Items Specifications Remark Output voltage Same as input voltage Output frequency Same as input 50 60 Hz Output current 16 A Max transfer time 15 ms Overload capability 105 125 20 A 45 sec 126 15...

Page 11: ...l Over Temperature PIN 2 Not used PIN 3 Not used PIN 4 Source 1 status signal Source 1 is fail Source 1 is ok PIN 5 Common PIN 6 Not used PIN 7 Overload signal Normal Over load PIN 8 Source 2 status signal Source 2 failed Source 2 OK PIN 9 Summary alarm signal Normal Alarm occurred Mechanical Features Items Specification Remark Dimensions W 430 mm D 315 mm H 44 mm 1U Weight Approx 8 kg Packaging s...

Page 12: ...ontinuous Storage humidity 10 to 90 Operation humidity 20 to 85 No condensation Operation Altitude max 1000 m Audible noise 25dBA max Buzzer OFF Cooling Natural Cooling IP Protection IP 30 Safety Standards Meets IEC60950 1 EMC Standard EMI IEC62310 2 C1 EMS IEC61000 4 2 level 3 IEC61000 4 3 level 2 Lab IEC61000 4 4 level 2 IEC61000 4 5 level 3 IEC 61000 2 2 LF Immunity IEC61000 4 6 level 2 Lab IEC...

Page 13: ...s Disconnecting devices must be provided in building installations and other locations All protection devices circuit breakers and fuses placed upstream of the ATS 16 A input and downstream to ATS 16 A output line have to be installed for the protection of both the cables and the equipment and in coordination with both ATS 16 A input protection fuses and ATS 16 A overload capacities WARNING IF THE...

Page 14: ...wing figure shows the back of the ATS 16 A with its connectors terminals and interfaces 3 6 Operating Panel In the following figure you can see the front panel of the ATS 16 A Most of the functions of the ATS 16 A are driven by an internal control From the operating panel mains electricity can be set as the preferred source of power The state of the relay group is displayed with several LEDs Pleas...

Page 15: ...normal no voltage is transferred to the output LED S1 Source S1 Line status LED LED GREEN Input source 1 is OK LED FLASH Input source 1 voltage frequency is out of range LED OFF Input source 1 failure no power from source LED S2 Source S2 Line status LED LED GREEN Input source 2 is OK LED FLASH Input source 2 voltage frequency is out of range LED OFF Input source 2 failure no power from source LED...

Page 16: ...ched to the other source The ATS 16 A is fitted with a block diagram with LED indicators capable of providing all the information concerning equipment operation status together with the power source priority selection button BP2 needed to enable trained operators to make full use of the apparatus Features Break Before Make transfer mode Back feed protection according EN62310 1 Complete overload an...

Page 17: ...nated o Priority LED PS1 or PS2 depending on the default setting o LED S1 o LED S2 o LED SW1 or SW2 according to the primary source 4 2 First Switch on from Source B Check that all switches are OFF and check the EPO status Input the mains for source B Wait for several seconds until the logic is enabled and the LEDs on the display are switched ON o Priority LED PS1 or PS2 depending on the default s...

Page 18: ...witched off Switch on the mains or feeding UPS units No mains voltage present Have the mains inspected by a quali fied electrician Input fuses tripped Check and make sure the load capac ity is within the specification then replace with new fuse If the problem persists contact the appropriate customer service representative Both mains indicator S1 and S2 do not illuminate when mains voltage present...