ABB AquaProbe FEA200 User Manual Download Page 8

AquaProbe FEA100 / FEA200

Electromagnetic flowmeter – insertion-type flow sensors

1 Safety

6

OI/FEA100/200–EN Rev. C 

1.9 Safety Conventions

1.10 Safety Recommendations

For safe operation, it is imperative that these service instructions be read before use and that the safety
recommendations mentioned herein be scrupulously respected. If danger warnings are not heeded to,
serious material or bodily injury could occur.

1.11 Service and Repairs

None of the instrument's components can be serviced by the user. Only personnel from ABB or its
approved representative(s) is (are) authorized to attempt repairs to the system and only components
formally approved by the manufacturer should be used. Any attempt at repairing the instrument in
contravention of these principles could cause damage to the instrument and corporal injury to the person
carrying out the repair. It renders the warranty null and void and could compromise the correct working of
the instrument and the electrical integrity or the CE compliance of the instrument. 

If you have any problems with installation, starting, or using the instrument please contact the company that
sold it to you. If this is not possible, or if the results of this approach are not satisfactory, please contact the
manufacturer's Customer Service

1.12 Potential Safety Hazards

The following potential safety hazards are associated with operating the analyzer: 

Electrical (line voltage) 

Potentially hazardous chemicals 

Warning.

In this manual, a warning is used to indicate a condition which, if not met, could cause serious 

personal injury and/or death. Do not move beyond a warning until all conditions have been met. 

If a warning sign appears on the instrument itself, refer to Precautionary Labels – UL Certification and 
Electrical Safety – CEI/IEC 61010-1:2001-2 for an explanation.

Caution.

A caution is used to indicate a condition which, if not met, could cause minor or moderate 

personal injury and/or damage to the equipment. Do not move beyond a caution until all conditions have 
been met. 

Note.

A note is used to indicate important information or instructions that should be considered before 

operating the equipment. 

Warning.

The installation of the instrument should be performed exclusively by personnel specialized 

and authorized to work on electrical installations, in accordance with relevant local regulations. 

Summary of Contents for AquaProbe FEA200

Page 1: ...eclude the use of conventional closed pipe meters This User Guide provides installation connection security start up and basic setup details for the flow sensor only The AquaProbe sensor is available for operation with either a WaterMaster transmitter FET100 or an AquaMaster3 transmitter FET200 This User Guide should be used in conjunction with the following publications WaterMaster flowmeter FEA1...

Page 2: ...re committed to teamwork high quality manufacturing advanced technology and unrivalled service and support The quality accuracy and performance of the Company s products result from over 100 years experience combined with a continuous program of innovative design and development to incorporate the latest technology Quality Control The UKAS Calibration Laboratory No 0255 is just one of the ten flow...

Page 3: ...cation Flow Conditions 10 3 3 1 International Standard for Flow Measurement 11 3 3 2 Velocity Limitations 11 3 4 Location Mechanical 13 3 5 Safety 14 3 6 Installing the Flow Sensor 15 3 7 Setting the Insertion Depth 16 3 7 1 Centre Line Method for Pipe Diameters 1 m 40 in 16 3 7 2 Centre Line Method for Pipe Diameters 1 m 2 m 40 in 80 in 17 3 7 3 Mean Axial Velocity Method 18 3 8 Flow Sensor Align...

Page 4: ...00 EN Rev C Appendix A 27 A 1 Velocity Profiles Background 27 A 2 Testing the Flow Profile for Symmetry 29 A 2 1 Partial Velocity Traverse 29 A 2 2 Single Entry Point Method 29 A 2 3 Dual Entry Point Method 30 A 3 Full Velocity Profile 30 Appendix B Measuring the Internal Diameter 31 Notes 32 ...

Page 5: ... To ensure that our products are safe and without risk to health the following points must be noted The relevant sections of these instructions must be read carefully before proceeding Warning labels on containers and packages must be observed Installation operation maintenance and servicing must only be carried out by suitably trained personnel and in accordance with the information given Normal ...

Page 6: ...als should handle chemicals or perform maintenance on chemical delivery systems associated with the equipment This symbol indicates the need for protective eye wear This symbol indicates the need for protective hand wear Electrical equipment marked with this symbol may not be disposed of in European public disposal systems In conformity with European local and national regulations European electri...

Page 7: ...lectrical and electronic equipment and improve the environmental performance of all those involved in the life cycle of electrical and electronic equipment In conformity with European local and national regulations EU Directive 2002 96 EC stated above electrical equipment marked with the above symbol may not be disposed of in European public disposal systems after 12 August 2005 The European Union...

Page 8: ...arting or using the instrument please contact the company that sold it to you If this is not possible or if the results of this approach are not satisfactory please contact the manufacturer s Customer Service 1 12 Potential Safety Hazards The following potential safety hazards are associated with operating the analyzer Electrical line voltage Potentially hazardous chemicals Warning In this manual ...

Page 9: ... part of the equipment and must be handled with care When the flow sensor is not in use fully retract the tip of the flow sensor and replace the end cap When removing inserting the flow sensor into the pipeline ensure that the valve is fully open Damage to the flow sensor affects the performance Physical damage to the flow sensor invalidates the warranty AquaMaster3 Flow Sensor or AquaMaster3 FET2...

Page 10: ...0 EN Rev C 3 Mechanical Installation 3 1 Location Environmental Conditions Fig 3 1 Environmental Requirements AquaMaster3 AquaMaster3 A Within Temperature Limits 20 C 4 F Minimum 10 m 30 ft C Avoid Excessive Vibration B Within Environmental Rating IP68 NEMA 6P 60 C 140 F Maximum D Protect Pressure Transducer from Frost ...

Reviews: